{"product_id":"honeywell-51304163-300-ucn-communication-modem-board","title":"Honeywell 51304163-300 UCN Communication Modem Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51304163-300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance Modem Board and UCN (Universal Control Network) Communication Module. This PLC Add-On board bridges the gap between the UCN architecture and external serial devices, enabling seamless data exchange across industrial networks. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your distributed control system maintains deterministic communication timing and robust protocol translation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 51304163-300 integrates multiple industrial protocols and physical interfaces into a single rack-mounted form factor.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51304163-300\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModem Board \/ UCN Communication Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUCN, Modbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232, RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Data Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Mbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 x 80 x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 lb (0.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Factory New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Protocol Translation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 51304163-300 handles both proprietary UCN and standard Modbus RTU protocols. This capability allows the Honeywell controller to poll third-party PLCs, power meters, or motor drives directly, consolidating your plant-floor data into a single DCS environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting data rates up to 1 Mbps, this board eliminates communication bottlenecks. It provides the bandwidth necessary for real-time process monitoring and rapid alarm propagation, which is vital for safety-instrumented functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Layer Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated RS-232 and RS-485 ports solve the industrial pain point of hardware incompatibility. Engineers can switch between short-range point-to-point connections (RS-232) and long-distance multi-drop networks (RS-485) without requiring external signal converters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell optimizes the onboard modem circuitry to reject the electromagnetic interference common in high-voltage switchgear rooms. This hardening ensures bit-perfect data transmission even in environments saturated with RFI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 51304163-300 require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe board operates on a standard 24 VDC input, typically sourced directly from the PLC backplane or the cabinet's instrument power rail. Always verify the voltage stability to ensure consistent modem performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between RS-232 and RS-485 modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInterface selection occurs through a combination of onboard jumper settings and software configuration within the Honeywell engineering environment. Refer to your specific system manual to set the correct termination resistors for RS-485 multi-drop loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this board for peer-to-peer UCN communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 51304163-300 acts as a primary node interface, allowing the controller to broadcast and receive data packets across the Universal Control Network for coordinated control strategy execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the unit is brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe ship each 51304163-300 in its original Honeywell antistatic factory packaging. The verifiable USA-origin serial numbers and pristine, unscratched connector pins guarantee that the board has never been field-installed or used as a test unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52880325148981,"sku":"51304163-300","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51304163-300.png?v=1778745583","url":"https:\/\/www.5gplc.com\/products\/honeywell-51304163-300-ucn-communication-modem-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}