{"product_id":"honeywell-51303944-100-tdc-3000-pni-paddle-card","title":"Honeywell 51303944-100 TDC 3000 PNI Paddle Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51303944-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance PNI (Process Network Interface) Paddle Card designed specifically for the Honeywell TDC 3000 Distributed Control System (DCS). This critical interface component facilitates the physical and electrical connection between the system backplane and external communication cables. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your legacy TDC 3000 infrastructure maintains optimal signal continuity and avoids the communication timeouts often caused by degraded contacts on used or refurbished cards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 51303944-100 features a ruggedized PCB architecture designed for long-term deployment in industrial marshalling cabinets.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51303944-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePNI Paddle Card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell TDC 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.7 cm x 12.7 cm x 12.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Factory New\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGold-Plated Contact Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 51303944-100 utilizes high-micron gold plating on its connector pins. This surface treatment prevents oxidation and fretting corrosion, ensuring a gas-tight seal that maintains low contact resistance even in the presence of corrosive atmospheric sulfur or high humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Signal Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis paddle card incorporates internal ground planes to shield sensitive communication signals from electromagnetic interference. This design effectively suppresses noise from adjacent high-voltage power components, preventing data corruption within the TDC 3000 network loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Mechanical Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a substantial 0.8 kg build quality, the card resists physical warping under thermal stress. The industrial-grade substrate maintains its structural integrity during repeated insertion and removal cycles, making it ideal for high-maintenance control environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Drop-in Replacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis factory-original paddle card adheres to the exact mechanical tolerances of the TDC 3000 chassis. It slides into the backplane slots with zero friction issues, ensuring the locking mechanisms engage perfectly for a vibration-proof installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 51303944-100 replace older PNI paddle card revisions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This model serves as a direct, high-spec replacement for earlier versions within the TDC 3000 PNI series. Installing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecard eliminates the intermittent \"No Response\" errors frequently associated with worn-out legacy interface hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this card require any software configuration during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe paddle card acts as a physical interface layer. While the associated PNI processor module requires software setup, the 51303944-100 itself is transparent to the system. Ensure all cable connections are secure and the card is fully seated to enable immediate communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary installation precautions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard ESD (Electrostatic Discharge) protocols must be followed. Use a grounded wrist strap when handling the card to prevent damage to sensitive surface-mount components. Always check the backplane connector for debris before insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify that this is a \"Factory New\" unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery 51303944-100 ships in its original Honeywell industrial packaging with intact factory seals. Each card includes a verifiable manufacturing barcode, guaranteeing that the product has never been previously installed or field-tested.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52880157901109,"sku":"51303944-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51303944-100.png?v=1778742620","url":"https:\/\/www.5gplc.com\/products\/honeywell-51303944-100-tdc-3000-pni-paddle-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}