{"product_id":"honeywell-51203330-300-3m-shielded-i-o-link-cable-assembly","title":"Honeywell 51203330-300 3m Shielded I\/O Link Cable Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51203330-300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51203330-300\u003c\/strong\u003e Cable Assembly, operates as a dedicated hardware component for high-speed I\/O link drop communication and signal routing between system controllers and Field Termination Assemblies (FTAs) within TDC 3000, Experion PKS, and TPS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51203330-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.0 m (approx. 10 ft) length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical link assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded Twisted Pair (STP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e30 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding Architecture\u003c\/td\u003e\n\u003ctd\u003eMulti-layer foil and braided shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eFactory-molded connectors at both ends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material \/ Flame Rating\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade PVC, UL 1581 VW-1 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocol Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe multi-layer foil and braided shielding architecture provides continuous channel-to-channel isolation against high-frequency electromagnetic interference (EMI) and radio frequency interference (RFI). Precision twisted-pair geometry maintains differential signal balance, preventing ground potential loops and crosstalk from corrupting digital data frames or 4-20 mA HART signal transmissions between remote I\/O modules and core process controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the cable construction suppress industrial electrical noise between I\/O racks?\u003c\/p\u003e\n\u003cp\u003eA: Dual-layer foil and braided copper shielding combined with precision twisted-pair conductors attenuate external electromagnetic interference and prevent cross-channel signal degradation.\u003c\/p\u003e\n\u003cp\u003eQ: Is field termination or crimping required for the 51203330-300 cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: No, the cable features pre-terminated factory-molded connectors on both ends designed for direct plug-and-play connection to I\/O link drop headers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect factory-molded connector pins and locking mechanisms for contamination or physical damage before cable deployment.\u003c\/li\u003e\n\u003cli\u003eRoute the 3-meter cable assembly through designated wireways, maintaining a minimum bend radius to prevent inner conductor stress.\u003c\/li\u003e\n\u003cli\u003eAlign connector keys with the corresponding controller and FTA I\/O link ports, pressing firmly until the connector latch fully engages.\u003c\/li\u003e\n\u003cli\u003eSeparate data cable paths from high-voltage AC distribution conduits to limit inductive coupling along the cable jacket.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67667357270325,"sku":"51203330-300","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202329-1022_Cocoai_c70ede8d-c484-45c1-946f-0b93f4e5e4da.png?v=1791612333","url":"https:\/\/www.5gplc.com\/products\/honeywell-51203330-300-3m-shielded-i-o-link-cable-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}