{"product_id":"honeywell-51202329-300-series-c-i-o-link-cable","title":"Honeywell 51202329-300 Series C I\/O Link Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51202329-300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51202329\u003c\/strong\u003e Series C I\/O Link Cable, operates as a dedicated hardware component for high-speed multi-drop signal transmission within Experion PKS C300 and Series C I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51202329-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3 meters (nominal length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (30 VDC rated voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded multi-core communication cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Configuration\u003c\/td\u003e\n\u003ctd\u003e3 drops (supports two CF9s, two C300s, one 6-inch I\/O module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eFactory-installed system-specific I\/O Link connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eFoil shielded for EMI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePVC (UL 94V-0 flame rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 51202329-300 communication assembly ensures signal preservation across distributed Series C I\/O topologies. Integrating channel-to-channel isolation principles across the local I\/O link bus, the cable structure isolates process controller communication channels from transient ground loops and differential common-mode noise. High-density foil shielding limits cross-talk and electromagnetic interference (EMI) during high-frequency data exchanges between C300 controllers, CF9 modules, and local I\/O carrier bases.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum voltage rating for the 51202329-300 cable assembly?\u003c\/p\u003e\n\u003cp\u003eA: The cable is insulation-rated for a maximum operating voltage of 30 VDC across all internal conductor pairs.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 51202329-300 cable support hot-swapping during active I\/O bus operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, physical connection or disconnection of the drop connectors can occur without removing system power, provided proper grounding practices are observed during insertion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet channel trays are clean and free of sharp metal edges before routing the cable assembly.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum bend radius of at least 10 times the outer cable diameter during installation to prevent internal foil shield tearing or conductor strain.\u003c\/li\u003e\n\u003cli\u003eSecure the factory-installed connectors firmly into the targeted C300 or CF9 carrier ports until the retaining clips engage completely.\u003c\/li\u003e\n\u003cli\u003eRoute the I\/O link drop cable through dedicated low-voltage trunking, maintaining separate pathways from high-voltage AC power wiring and motor lead conduits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53635069116725,"sku":"51202329-300","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202329-102_Cocoai_88252cf6-18b1-4309-b8cf-630ee503a1ed.png?v=1790221074","url":"https:\/\/www.5gplc.com\/products\/honeywell-51202329-300-series-c-i-o-link-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}