{"product_id":"honeywell-51202329-111-series-c-i-o-link-cable-cable-b-6-drop","title":"Honeywell 51202329-111 Series C I\/O Link Cable (Cable B) 6-Drop","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51202329-111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the secondary (Redundant) communication backbone for the Experion PKS Series C platform. Specifically designated as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCable B\u003c\/strong\u003e, this high-performance I\/O Link Cable facilitates synchronized data exchange between C300 controllers and Series C Input\/Output Modules (IOMs). It works in tandem with the \"Cable A\" assembly to provide a fully redundant communication path, ensuring zero process interruption if the primary link fails. We provide this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory condition\u003c\/strong\u003e, guaranteeing the signal integrity required for mission-critical industrial automation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 51202329-111 adheres to stringent Honeywell Series C electrical and mechanical standards:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51202329-111\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSeries C I\/O Link Cable (Cable B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDrop Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Module Drops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePitch\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 inches (152 mm) between drops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Series C IOMs \/ C300 Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Role\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundant Path (B-Link)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFail-Safe Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs the designated \"Cable B,\" this assembly completes the redundant I\/O Link pair. The C300 controller utilizes this secondary path to maintain continuous data flow, preventing system trips during primary cable damage or port failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Standard Pitch:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 6-inch (152 mm) spacing between drops matches the horizontal mounting dimensions of Series C IOTAs. This ensures a clean, professional installation without the need for manual cable management or excess loop storage within the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial EMI Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced internal shielding rejects electromagnetic interference (EMI) from neighboring power cables and VFDs. This protection maintains high signal-to-noise ratios, which is vital for the high-speed serial communication required by Series C modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Connector Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe multi-drop connectors feature high-retention locking clips. These ensure a gas-tight electrical connection that resists the vibration and thermal cycling common in heavy industrial environments, eliminating \"intermittent node\" errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use 51202329-111 as a standalone cable if I don't need redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, however, Honeywell standard practice designates the -111 as the \"B\" link. For non-redundant systems, you typically use \"Cable A.\" If using this for a single link, ensure the controller configuration matches the physical port (Link B) to avoid system alarms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the physical difference between 51202329-111 and 51202329-110?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMechanically and electrically, they are similar, but they carry different labels and often different jacket colors (typically Violet for A and White or Gray for B) to help technicians distinguish the primary path from the redundant path during maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this cable require any termination resistors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Series C I\/O Link architecture manages termination through the IOTA hardware. This cable provides the physical drops; you must ensure your I\/O Link is properly terminated at the end of the chain according to Honeywell's Series C installation guidelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit a \"New Surplus\" item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. We guarantee this is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal product. Unlike surplus cables that may suffer from insulation hardening or connector oxidation due to long-term uncontrolled storage, our new stock ensures maximum flexibility and conductivity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52866742321461,"sku":"51202329-111","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51202329-110_8cc5fb80-9fa1-41e5-97dd-631085c90f67.png?v=1778576677","url":"https:\/\/www.5gplc.com\/products\/honeywell-51202329-111-series-c-i-o-link-cable-cable-b-6-drop","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}