{"product_id":"honeywell-51201748-210-peripheral-power-supply-load-resistor-kit","title":"Honeywell 51201748-210 Peripheral Power Supply Load Resistor Kit","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51201748-210\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51201748-210\u003c\/strong\u003e Power Supply Load Resistor Kit, operates as a dedicated hardware component for power supply load simulation and diagnostic loop verification within Honeywell Series C and Experion PKS system enclosures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51201748-210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.60 kg (1.32 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Load Element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003ePower Components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSubcategory\u003c\/td\u003e\n\u003ctd\u003eResistor Kit \/ Dummy Load Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003ePeripheral power supply load simulation and troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Block \/ Power Bus Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Process Power Supply Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Power Simulation\u003c\/h3\u003e\n\u003cp\u003eThe 51201748-210 load resistor assembly provides a minimum baseline current draw on power supply rails during maintenance and loop staging. In architectures featuring 4-20 mA HART loop protocol field wiring and multi-channel analog modules, power distribution units require minimum current threshold loads to maintain regulated DC output voltages.\u003c\/p\u003e\n\u003cp\u003eConnecting the resistive load element across the bus channels stabilizes system regulation, protecting sensitive channel-to-channel isolation circuits from overvoltage transients during open-circuit test conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary technical function does the 51201748-210 load resistor serve?\u003c\/p\u003e\n\u003cp\u003eA: The kit simulates active field load conditions on Honeywell system power supplies to enable functional bench testing and diagnostic fault isolation without connected I\/O hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 51201748-210 assembly remain connected continuously in a live control panel?\u003c\/p\u003e\n\u003cp\u003eA: It is primarily utilized during commissioning and maintenance; continuous integration depends on power supply minimum load specifications and panel heat dissipation budgets.\u003c\/p\u003e\n\u003cp\u003eQ: How is the assembly physically integrated into the system power rail?\u003c\/p\u003e\n\u003cp\u003eA: The module attaches directly across designated output power terminal blocks or backplane distribution busses using standard screw connection terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure power supply outputs are de-energized prior to installing or removing the 51201748-210 resistor assembly to prevent electrical arcing.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the resistive body to allow convective heat dissipation under energization.\u003c\/li\u003e\n\u003cli\u003eVerify screw-terminal connections are torqued according to panel specifications to maintain low-resistance electrical contact.\u003c\/li\u003e\n\u003cli\u003eRoute adjacent low-voltage sensor and communication wiring away from thermal dissipation paths created by passive load resistors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53196822675765,"sku":"51201748-210","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51201748-110_9da868a5-c1ce-4128-b7b5-58929f4a2cbc.png?v=1784692647","url":"https:\/\/www.5gplc.com\/products\/honeywell-51201748-210-peripheral-power-supply-load-resistor-kit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}