{"product_id":"honeywell-51201397-002-xpm-power-distribution-interface-cable","title":"Honeywell 51201397-002 XPM Power Distribution Interface Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51201397-002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical power link within XPM (Extended Process Manager) architectures. This 2-meter interface cable facilitates the direct transfer of energy from the XPM to either Digital Input (DI) or Galvanic Isolation (GI) Power Distribution Assemblies. Engineered for high-integrity industrial control environments, this single-cable solution ensures consistent voltage delivery without the need for an I\/O link protector module. We supply this component in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory condition\u003c\/strong\u003e, ensuring your DCS infrastructure maintains its factory-rated safety and performance standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 51201397-002 utilizes industrial-grade conductors designed for low-impedance power transmission:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51201397-002\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Distribution Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Meters (6.56 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXPM to DI or GI Power Distribution Assemblies\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Cable (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal or External to Cabinet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.65 lbs (0.29 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Routing Capabilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 51201397-002 features a robust jacket rated for both internal and external cabinet routing. This flexibility allows engineers to bridge power gaps between adjacent racks or remote distribution panels without compromising signal shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy eliminating the requirement for an I\/O link protector module, this cable streamlines the power distribution chain. It reduces potential points of failure and simplifies the bill of materials (BOM) for system expansions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-molded connectors ensure low-resistance contact with the Power Distribution Assembly. This precise fit prevents micro-arcing and localized heating, common issues in field-crimped alternatives that lead to intermittent power drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable construction incorporates high-grade insulation that rejects electromagnetic interference. This protects the power rail from high-frequency noise generated by nearby Variable Frequency Drives (VFDs) or heavy switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 51201397-002 require an I\/O Link Protector Module for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. Honeywell specifically designed this part number for configurations that do not utilize the I\/O link protector module. It provides a direct, high-integrity connection between the XPM and the distribution assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this cable for both DI and GI Power Distribution Assemblies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This cable supports both Digital Input (DI) and Galvanic Isolation (GI) power distribution architectures, making it a versatile spare part for Honeywell DCS maintenance teams.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this a \"New Surplus\" item or a \"Brand New\" factory-sealed product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal product. We guarantee that the cable has never been installed and has remained in a climate-controlled environment to prevent the insulation degradation often found in surplus stock.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum current capacity of this 2-meter cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis cable matches the specific power ratings of the Honeywell XPM system backplane. For exact amperage limits, please refer to your specific XPM Power Distribution Assembly manual to ensure total load compliance.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52866625110325,"sku":"51201397-002","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51201397-002.png?v=1778575161","url":"https:\/\/www.5gplc.com\/products\/honeywell-51201397-002-xpm-power-distribution-interface-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}