{"product_id":"honeywell-51200873-100-cable-assembly","title":"Honeywell 51200873-100 Cable Assembly","description":"\u003cp\u003eConfigured for internal signal interconnectivity in High-Performance Process Manager platforms, the \u003cstrong\u003eHoneywell 51200873-100\u003c\/strong\u003e (\u003cstrong\u003e51200873-100\u003c\/strong\u003e Cable Assembly) provides direct physical\/electrical execution across distributed system racks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51200873-100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard cable assembly length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +75 deg C (UL Type CL2 rated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive physical bus assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Revision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRev D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Part Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5C52C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Structure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2C\/20 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL Type CL2 75 deg C \/ AWM 2464 CSA AW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProcess Manager \/ TDC 3000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 2C\/20 AWG conductor geometry incorporates high-dielectric insulation barriers designed to maintain channel-to-channel isolation and limit electromagnetic coupling across adjacent field signal runs. Ground differential decoupling along the shielded twisted conductors prevents noise insertion into sensitive 4-20 mA HART analog input loops. High-grade outer jacket jacketing minimizes signal attenuation and phase distortion during real-time serial frame transmission across cabinet backplanes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What insulation rating and conductor size are utilized in the 51200873-100 cable construction?\u003c\/p\u003e\n\u003cp\u003eA: The cable utilizes 2-conductor 20 AWG (2C\/20 AWG) wiring certified under UL Type CL2 for temperatures up to 75 deg C and CSA AWM 2464 standards.\u003c\/p\u003e\n\u003cp\u003eQ: Is this cable assembly directional or requires active power supply termination?\u003c\/p\u003e\n\u003cp\u003eA: No, it is a passive physical inter-module cable assembly that provides point-to-point electrical continuity between header connectors without requiring power or active electronic components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInspect cable header pins and insulation jackets for damage or tears prior to cabinet placement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain specified bend radius limits along panel wire channels to avoid mechanical stress on internal 20 AWG conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute cable runs separately from high-voltage AC conductors to limit inductive noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure terminal connections fully to ensure reliable earth ground bonding through designated cabinet shield buses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67667041157429,"sku":"51200873-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51200873-100_Cocoai.png?v=1791603562","url":"https:\/\/www.5gplc.com\/products\/honeywell-51200873-100-cable-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}