{"product_id":"honeywell-51196041-100-lcn-a-b-tee-connector-set","title":"Honeywell 51196041-100 LCN A-B TEE Connector Set","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51195041-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51196041\u003c\/strong\u003e TEE Connector Set, operates as a dedicated hardware component for coaxial signal splitting and drop cable routing within Local Control Network (LCN) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51196041-100 (51196041)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.05 kg (0.11 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard BNC TEE connector geometry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive physical transmission media (0 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBNC (Male to dual Female)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResistor Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-resistor configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCN Dual-Coaxial Bus (Channel A \/ B)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 51196041-100 TEE connector set routes dual high-frequency coaxial signals from the main Local Control Network (LCN) trunk cables directly into local node interface boards, supporting pass-through digital communication and field telemetry for 4-20 mA HART loop protocol devices. The non-resistor internal bus structure provides uninterrupted signal path continuity while maintaining galvanic isolation between physical channel A and channel B paths. Metal-shielded BNC housings mitigate high-frequency electromagnetic noise and prevent ground-loop voltage shifts from compromising high-speed bus arbitration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 51196041-100 TEE connector set be used as a bus line termination point?\u003c\/p\u003e\n\u003cp\u003eA: No. The 51196041-100 is a non-resistor TEE connector designed strictly for tap drops. Terminating an LCN bus end requires a dedicated 75 ohm or 50 ohm BNC terminating resistor to eliminate signal reflections.\u003c\/p\u003e\n\u003cp\u003eQ: Does disconnecting a BNC cable from the TEE connector disrupt network communication?\u003c\/p\u003e\n\u003cp\u003eA: Removing a drop cable from the stem port allows main trunk traffic to continue, but disconnecting either arm of the inline trunk connection will break the physical coaxial loop and trigger an LCN communication failover.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Coupling\u003c\/strong\u003e: Align the twist-lock bayonet pins with the mating socket slots and turn clockwise until fully seated and locked in position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrain Relief\u003c\/strong\u003e: Secure adjacent coaxial cabling to enclosure cable cleats to prevent mechanical tension on the BNC connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Verify ground continuity through the outer metallic shield shell to preserve single-point earthing specifications across cabinet boundaries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Separation\u003c\/strong\u003e: Maintain a minimum 300 mm spacing from high-voltage AC motor wires and power lines to reduce electrical noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67654463815989,"sku":"51196041-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51196041-100.png?v=1791438856","url":"https:\/\/www.5gplc.com\/products\/honeywell-51196041-100-lcn-a-b-tee-connector-set","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}