{"product_id":"honeywell-51195479-300-experion-pks-i-o-link-cable-assembly","title":"Honeywell 51195479-300 Experion PKS I\/O Link Cable Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51195479-300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51195479-300\u003c\/strong\u003e I\/O Link Cable Assembly, operates as a dedicated hardware component for high-speed serial data transmission between I\/O modules and control processors within Honeywell Experion PKS and TDC 3000 platforms. It provides direct physical execution of differential bus signaling using Honeywell-specific keyed connectors and integrated shield terminations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51195479-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.39 lbs (0.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O Link Trunk\/Drop Assembly Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Cable Assembly (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eHoneywell-Specific Keyed Interface Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Category\u003c\/td\u003e\n\u003ctd\u003eIndustrial Shielded Computer Bus Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eMulti-Layer Foil\/Braid EMI\/RFI Shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS and TDC 3000 Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Bus Topology\u003c\/h3\u003e\n\u003cp\u003eThe 51195479-300 cable routing ensures physical signal integrity across redundant I\/O link channels in Honeywell DCS topologies. Integrated foil and braided shielding suppresses ground-loop noise and common-mode transient voltages caused by heavy industrial machinery, preventing frame-drop errors during real-time data frame transfers. This low-attenuation bus link operates in tandem with field termination blocks processing 4-20 mA HART loop protocol signals, preserving continuous telemetry communication between distributed I\/O racks and process control nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the connectors on the 51195479-300 cable assembly keyed to prevent incorrect insertion?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the assembly utilizes Honeywell-specific keyed connectors to prevent cross-wiring between primary and redundant I\/O link interface ports.\u003c\/p\u003e\n\u003cp\u003eQ: Does the cable assembly require external grounding clamps for EMI protection?\u003c\/p\u003e\n\u003cp\u003eA: Shield continuity is established through the metallic backshells of the keyed connectors, grounding automatically to the chassis ground frame upon full engagement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect connector pins and housing keyways for physical debris or bent pins prior to installation.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum bend radius along the cable run to avoid conductor strain and shield degradation.\u003c\/li\u003e\n\u003cli\u003eFully seat the keyed connectors into the corresponding I\/O link interface sockets on the controller base chassis and I\/O carrier.\u003c\/li\u003e\n\u003cli\u003eTighten connector thumbscrews or locking latches securely to guarantee continuous shield connection and mechanical retention under thermal expansion.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53599443616053,"sku":"51195479-300","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51195479-300_Cocoai.png?v=1789617177","url":"https:\/\/www.5gplc.com\/products\/honeywell-51195479-300-experion-pks-i-o-link-cable-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}