{"product_id":"honeywell-51195096-200-input-output-circuit-board","title":"Honeywell 51195096-200 Input\/Output Circuit Board","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51195096-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51195096-200\u003c\/strong\u003e Input\/Output Circuit Board, operates as a dedicated hardware component for PLC Gateway interface communications within Honeywell TDC 3000 systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51195096-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.68 kg (1.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell TDC 3000 rack module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 12 W via chassis backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eTDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus, non-redundant Allen-Bradley protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable Logic Controller Interface (PLCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eCE Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eChassis \/ Rack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe board enables continuous serial data conversion between the proprietary Honeywell TDC 3000 backplane architecture and external field PLCs running Modbus or Allen-Bradley protocols. High-grade channel-to-channel isolation safeguards the digital communication circuits against ground loops and common-mode voltage spikes, preventing noise propagation into analog 4-20 mA HART loop protocol signal paths operating within the same DCS enclosure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 51195096-200 board support redundant Allen-Bradley protocol links?\u003c\/p\u003e\n\u003cp\u003eA: No, the board hardware is designed specifically for non-redundant Allen-Bradley communication paths alongside standard Modbus interface links.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the TDC 3000 rack backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: No, power to the rack backplane section must be isolated before removing or inserting the circuit board to prevent bus voltage transients and physical trace damage.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical protocol connectivity achieved on this card?\u003c\/p\u003e\n\u003cp\u003eA: Communication cabling attaches via dedicated backplane pin arrays or faceplate cable headers configured for serial RS-232\/RS-422\/RS-485 level signaling to the external PLC network.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure backplane power supply rails are completely turned off prior to inserting the circuit card into the rack slot.\u003c\/li\u003e\n\u003cli\u003eGround the chassis frame in accordance with plant DCS grounding standards before connecting external serial communication cables.\u003c\/li\u003e\n\u003cli\u003eSecure all interface cable retention screws to prevent signal loss from mechanical vibration in cabinet environments.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate vertical ventilation clearances within the TDC 3000 rack cabinet to prevent thermal stress on onboard semiconductors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53635279323445,"sku":"51195096-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51195096-200_Cocoai.png?v=1790232334","url":"https:\/\/www.5gplc.com\/products\/honeywell-51195096-200-input-output-circuit-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}