{"product_id":"honeywell-16644992-001-digital-output-module","title":"Honeywell 16644992-001 Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 16644992-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e16644992\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete output signal control within Honeywell TDC 3000 and Universal Station platforms. The module provides direct physical execution of discrete digital switching commands across the system backplane matrix, translating software logic transitions into clean, non-latching electrical control states for field equipment receivers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16644992-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard DCS slot module assembly weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eProprietary Honeywell TDC 3000 card chassis index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial control room environment limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell module backplane power profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete digital switching outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Universal Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Integrity\u003c\/td\u003e\n\u003ctd\u003eLow-noise, interference-protected output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in module for Honeywell system backplanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell DCS Channel-to-Channel Isolation Parameters\u003c\/h3\u003e\n\u003cp\u003eThe hardware architecture uses high-density optocoupler matrices to secure channel-to-channel isolation limits across the discrete digital switching loops. This preventative electrical separation boundary isolates the internal system bus logic from high-frequency noise spikes and ground differentials, preventing external line transients from impacting parallel 4-20 mA HART loop protocol installations or causing parity errors on the host rack processor card.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 16644992-001 digital module support online hot-swap maintenance operations?\u003c\/p\u003e\n\u003cp\u003eA: No, live removal of the card assembly from an active TDC 3000 backplane can trigger transient electrical faults and system interlocks; the local chassis slot power must be isolated prior to hardware physical extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How does the interface suppress low-frequency induction noise across the digital lines?\u003c\/p\u003e\n\u003cp\u003eA: The board layout integrates passive RC filter networks and physical grounding shields alongside the output switches to suppress magnetic cross-talk and maintain low-noise signal profiles under full industrial loads.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the targeted TDC 3000 backplane slot segment before presenting the module to the card cage alignment rails.\u003c\/li\u003e\n\u003cli\u003eSlide the module smoothly along the structural guide tracks, pressing firmly until the heavy-duty multi-pin rear connector seats completely into the backplane socket.\u003c\/li\u003e\n\u003cli\u003eTighten the integrated faceplate mechanical locking screws to anchor the assembly against persistent ambient industrial vibrations.\u003c\/li\u003e\n\u003cli\u003eSeparate external digital field wiring routes from high-voltage AC cables in the terminal cabinet to mitigate electromagnetic cross-talk risks.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53164141838645,"sku":"16644992-001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/16644992-001.png?v=1784275547","url":"https:\/\/www.5gplc.com\/products\/honeywell-16644992-001-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}