{"product_id":"honeywell-16-channel-analog-output-fta-module-mu-mc-taox12-51304441-175","title":"Honeywell 16-Channel Analog Output FTA Module | MU\/MC-TAOX12 51304441-175","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMC-TAOX12 (51304441-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust Field Termination Assembly (FTA) designed to serve as the physical interface between Honeywell high-level analog output processors and field-mounted equipment. Supporting 16 independent channels, this assembly is engineered for the HPM (High-Performance Process Manager), TDC 3000, and Experion PKS environments. Its primary role is the precise distribution of 4–20 mA control signals to critical actuators and valves. Built for mission-critical reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMC-TAOX12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates redundant I\/O configurations, ensuring that process control remains uninterrupted even during processor failover or maintenance procedures.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMC-TAOX12\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51304441-175\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Type\u003c\/strong\u003e: Analog Output Field Termination Assembly (FTA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Density\u003c\/strong\u003e: 16 Isolated Signal Paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Protocol\u003c\/strong\u003e: 4–20 mA DC Current Loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArchitecture Support\u003c\/strong\u003e: Honeywell HPM, TDC 3000, and Experion PKS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Capability\u003c\/strong\u003e: Supports dual I\/O Link cable connections for redundant processors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Method\u003c\/strong\u003e: Compression-style screw terminals for secure field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24V DC Nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Coating\u003c\/strong\u003e: Conformal coating for moisture and corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e: Standard 6-inch FTA profile for cabinet mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIndustrial Application Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMC-TAOX12 (51304441-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the industry standard for driving final control elements in heavy industrial sectors. It is frequently utilized for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManaging 4–20 mA modulating control valves in high-pressure steam or chemical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransmitting precise speed setpoints to Variable Frequency Drives (VFDs) for pump control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing with I\/P (Current-to-Pressure) transducers for pneumatic instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eServing as a reliable replacement during legacy TDC 3000 to Experion PKS system migrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat differentiates the MC-TAOX12 from the MU-TAOX12?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMC-TAOX12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a conformal coating on the PCB, providing essential protection against humidity and atmospheric contaminants. The MU-prefix version is non-coated and intended for strictly controlled environments. Both share the same\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51304441-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctional circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre precision input resistors integrated into this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Unlike analog input boards (HLAI) that require 250-ohm resistors to convert current to voltage, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMC-TAOX12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an output device designed solely to drive current loops for field actuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52454643990837,"sku":"MU\/MC-TAOX12 51304441-175","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MUMC-TAOX1251304441-175.jpg?v=1773903462","url":"https:\/\/www.5gplc.com\/products\/honeywell-16-channel-analog-output-fta-module-mu-mc-taox12-51304441-175","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}