{"product_id":"honeywell-10205-2-1-fail-safe-analog-output-module","title":"Honeywell 10205\/2\/1 Fail-Safe Analog Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 10205\/2\/1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e10205\/2\/1\u003c\/strong\u003e Fail-Safe Analog Output Module, operates as a dedicated hardware component for 0(4)-20 mA current loop safety control execution within Fail Safe Controller (FSC) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10205\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.00 kg shipping weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e325 x 150 x 150 mm (4 HP, 3U chassis space)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 30 mA, 24 VDC at 65 mA (+ 30 mA per active output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 active or passive channels (12-bit D\/A conversion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA \/ 4-20 mA (Off current \u0026lt; 0.05 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1000 ohm maximum (30 VDC maximum output voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePassive External Voltage\u003c\/td\u003e\n\u003ctd\u003e40 VDC maximum (minimum voltage drop = 7.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatchdog Input Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module provides galvanic isolation between internal power rails and output current channels, with 0V 1 and 0V 2 internally interconnected to stabilize signal reference levels. This isolation architecture prevents ground loop interference, common-mode potential shifts, and external noise transients on active or passive field loops from coupling into adjacent analog processing channels or corrupting 4-20 mA HART loop protocol signals on connected process lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is hardware calibration performed on the 10205\/2\/1 analog output channels?\u003c\/p\u003e\n\u003cp\u003eA: Channel zero and span calibration is executed using potentiometers P2 and P3 on the module, monitored via a multimeter connected through an extender module and flat cable assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What key coding arrangement prevents incorrect module insertion into the rack slot?\u003c\/p\u003e\n\u003cp\u003eA: Physical key coding utilizes holes at locations A9 and C5 on the module, matching large key pins at locations A9 and C5 on the rack backplane.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 10205\/2\/1 output channels drive passive loops powered by an external source?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each channel can operate in passive mode powered by an external supply up to 40 VDC, maintaining a minimum internal voltage drop of 7.5 V.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify rack key coding alignment (pins A9 and C5) before inserting the module into the designated 4 HP width rack slot.\u003c\/li\u003e\n\u003cli\u003eDe-energize the cabinet rack backplane or ensure the proper safety system bypass procedures are engaged prior to extraction or insertion.\u003c\/li\u003e\n\u003cli\u003eSecure field cabling connections to output terminals, ensuring proper shielding termination to prevent electromagnetic interference on 0(4)-20 mA lines.\u003c\/li\u003e\n\u003cli\u003eEnsure minimum voltage drop requirements (= 7.5 V) are maintained across the terminals when interfacing external power supplies in passive loop mode.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53635167289653,"sku":"10205\/2\/1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1020521_Cocoai.png?v=1790229242","url":"https:\/\/www.5gplc.com\/products\/honeywell-10205-2-1-fail-safe-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}