{"product_id":"honeywell-10106-2-1-fsc-16-channel-fail-safe-digital-input-module","title":"Honeywell 10106\/2\/1 FSC 16-Channel Fail-Safe Digital Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 10106\/2\/1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e10106\/2\/1\u003c\/strong\u003e Fail-Safe Digital Input Module utilized to execute line-monitored digital signal acquisition across Honeywell FSC safety system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10106\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ OEM Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25 x 140 x 191 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~5 W (24 VDC +\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 independent digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDry contact or 24 VDC signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1500 VAC channel-to-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED indicators for power, input status, and fault diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail or rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Line Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe module integrates channel-to-channel isolation rated above 1500 VAC to safeguard internal backplane processing logic from field line surges and cross-channel noise coupling. Integrated line-monitoring capabilities enable continuous loop diagnostic validation for short-circuit and open-circuit states across 24 VDC or dry contact field wiring loops, executing state transfers with loop latencies below 10 ms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input types and response speeds are supported across the 16 channels?\u003c\/p\u003e\n\u003cp\u003eA: The module supports dry contact inputs and 24 VDC field signals, operating with a deterministic signal response time of less than 10 ms.\u003c\/p\u003e\n\u003cp\u003eQ: How does electrical isolation protect individual signal paths on this module?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic channel-to-channel isolation exceeding 1500 VAC prevents voltage transients and ground loops on one input circuit from impacting adjacent channels or central system backplane communications.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic feedback is provided directly on the front panel?\u003c\/p\u003e\n\u003cp\u003eA: Front-panel LED indicators display real-time power rail status, individual channel digital input logic states, and hardware fault conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure main power is disconnected from the subrack prior to inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eSecure the 25 mm wide module on the DIN rail or within the designated 19-inch rack slot, verifying proper backplane connector engagement.\u003c\/li\u003e\n\u003cli\u003eFasten external panel retaining screws to ensure continuous enclosure grounding and mechanical retention against vibration.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring for dry contacts or 24 VDC lines away from high-voltage power conduits, maintaining signal cable shielding integrity down to field junction boxes.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52431203139893,"sku":"10106\/2\/1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1010621.jpg?v=1773296041","url":"https:\/\/www.5gplc.com\/products\/honeywell-10106-2-1-fsc-16-channel-fail-safe-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}