{"product_id":"honeywell-10018-e-e-fail-safe-control-fsc-ethernet-communication-module","title":"Honeywell 10018\/E\/E Fail Safe Control (FSC) Ethernet Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 10018\/E\/E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core Ethernet communication interface within the Fail Safe Control (FSC) system architecture. This module enables high-speed data exchange between the safety controller and external networks, ensuring real-time monitoring and diagnostic reporting for critical safety-instrumented functions (SIF). Although the manufacturer has discontinued the FSC line, we supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original factory condition\u003c\/strong\u003e, allowing you to maintain your certified safety systems without undergoing an expensive and time-consuming full-system migration.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 10018\/E\/E provides the structural backbone for network integration in high-integrity environments:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFail Safe Control (FSC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication \/ Hardware Structure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRJ45 \/ Standard Network Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs (0.91 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFSC System Rack \/ Chassis Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell FSC Safety Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscontinued by Manufacturer (Supported via New-Old Stock)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Data Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10018\/E\/E handles critical safety data packets with minimal latency. It ensures that the safety logic solver communicates state changes to the HMI or Distributed Control System (DCS) without interruption, which is vital for Emergency Shutdown (ESD) applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module incorporates robust internal isolation to prevent electrical transients from the network side from reaching the safety backplane. This hardware-level protection secures the processor from external surges and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Legacy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module fits directly into the existing FSC hardware structure. It utilizes standard configuration parameters, allowing engineers to replace faulty network modules without rewriting the underlying safety application or modifying the rack's physical wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a heavy-duty metal enclosure that mitigates electromagnetic interference. This design ensures stable Ethernet performance even when installed in close proximity to high-voltage switchgear or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 10018\/E\/E replace older non-Ethernet FSC communication cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module specifically supports Ethernet-based communication. If you are upgrading from serial-based communication, you must verify your FSC system firmware version and network configuration to ensure compatibility with the Ethernet protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require specialized software for IP address configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You configure the 10018\/E\/E through the Honeywell FSC programming environment. You must assign a static IP address to ensure persistent communication within the safety network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this a refurbished or pull-off unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. We guarantee this 10018\/E\/E is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. We specialize in providing unused, original factory hardware to ensure your Safety Instrumented System (SIS) maintains its original reliability ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the installation requirements for heat dissipation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the FSC rack has adequate clearance for vertical airflow. The 10018\/E\/E relies on natural convection cooling; therefore, maintaining clear ventilation paths within the cabinet prevents thermal degradation of the internal communication chips.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52865917944117,"sku":"10018\/E\/E","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/10018-E-E.png?v=1778557940","url":"https:\/\/www.5gplc.com\/products\/honeywell-10018-e-e-fail-safe-control-fsc-ethernet-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}