{"product_id":"honeywell-07728000-plc-digital-i-o-module","title":"Honeywell 07728000 PLC Digital I\/O Module","description":"\u003cp\u003eConfigured for direct digital signal acquisition and command transmission in Experion PKS C300 systems, the \u003cstrong\u003eHoneywell 07728000\u003c\/strong\u003e (\u003cstrong\u003e07728000\u003c\/strong\u003e PLC Digital I\/O Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e07728000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 80 x 31 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e16 DI \/ 16 DO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Execution\u003c\/td\u003e\n\u003ctd\u003eDiscrete digital input\/output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 07728000 digital I\/O module integrates into C300 backplane architectures that manage 4-20 mA HART loop protocol diagnostics across hybrid control topologies. Channel-to-channel isolation prevents common-mode noise and ground loops from compromising backplane logic during rapid discrete switching cycles. Integrated cold junction compensation (CJC) processing supports adjacent hybrid temperature monitoring channels within the local enclosure. Connection to the Honeywell Control Bus enables localized digital status reporting and seamless data pass-through to FOUNDATION Fieldbus and Profibus PA network structures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 07728000 module support hot-swapping during runtime?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the C300 series backplane architecture permits hot-swapping this module without removing backplane power or halting host C300 controller execution.\u003c\/p\u003e\n\u003cp\u003eQ: Is external surge suppression required for the 24 VDC digital inputs?\u003c\/p\u003e\n\u003cp\u003eA: Internal transient protection is present, but external surge suppression devices are recommended for long field cable runs exposed to high inductive switching loads.\u003c\/p\u003e\n\u003cp\u003eQ: How is redundant configuration implemented for this module?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy is achieved by installing two 07728000 modules on a paired C300 I\/O carrier, where the Honeywell Control Bus manages real-time primary-to-secondary failover based on hardware health diagnostics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign module backplane pins with the C300 series cabinet carrier slot and seat firmly until the locking tab engages.\u003c\/li\u003e\n\u003cli\u003eConnect the cabinet ground lug directly to the module chassis grounding point to preserve galvanic isolation and discharge static voltage.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC digital I\/O wiring through dedicated wire ducts, keeping field signal leads separated from high-voltage AC lines.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for extended input\/output runs and land the cable shield at the cabinet entry ground bus.\u003c\/li\u003e\n\u003cli\u003eVerify power supply tolerances remain strictly within 24 VDC +\/- 10% under full load prior to commissioning field channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53188050780469,"sku":"07728000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/51199165-100_6903a38f-87da-4d8f-a0ef-576fcd613f39.png?v=1784532614","url":"https:\/\/www.5gplc.com\/products\/honeywell-07728000-plc-digital-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}