{"product_id":"honeywell-05701-a-0361-analytical-engineering-card","title":"Honeywell 05701-A-0361 Analytical Engineering Card","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 05701-A-0361\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e05701-A-0361\u003c\/strong\u003e Engineering Card, operates as a dedicated hardware component for centralized system commissioning and operational control within System 57 gas detection racks. This module provides a common interface to execute administrative functions, including channel configuration, zero signal adjustment, and span calibration for all fitted control cards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e05701-A-0361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.152 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e132 mm x 25 mm x 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eConsult System 57 rack specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 05701-A-0361 facilitates the management of 4-20 mA signaling loops across the System 57 architecture. By providing a common interface for bead mA alarms and zero\/span adjustments, the module ensures precise calibration of the analog output signals generated by individual control cards. Users utilize the push-button array to verify loop performance, ensuring that the 4-20 mA output remains within nominal ranges during both commissioning and routine diagnostic maintenance. Proper synchronization via the engineering card is necessary to maintain the integrity of the process variable reported to external DCS or PLC systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the engineering card be inserted or removed while the System 57 rack is under power?\u003c\/p\u003e\n\u003cp\u003eA: No. Hot-swapping is prohibited. De-energize the rack before installation or removal to prevent electrical arcing and potential corruption of the backplane communication signals.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module store configuration data for the control cards?\u003c\/p\u003e\n\u003cp\u003eA: The module acts as an interface for commissioning and operational commands. Configuration settings are typically maintained by the individual control cards or the central controller; the engineering card provides the manual entry point for these functions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e: Insert the engineering card into the designated slot within the 19-inch subrack. Ensure the card is fully seated and the rear backplane connector is aligned before applying pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Operation\u003c\/strong\u003e: Use the integrated push-button array to navigate commissioning functions. Simultaneous engagement of the Up and Down buttons triggers the Print function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Monitoring\u003c\/strong\u003e: Observe the front panel LEDs during operation. A green LED indicates Power On status, while a red LED signifies the Unlocked state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The subrack must be secured to a common equipment ground. Ensure the engineering card is fully seated to maintain the required chassis ground continuity through the mechanical rail interface.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52972193481013,"sku":"05701-A-0361","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/05701-A-0361.png?v=1780899735","url":"https:\/\/www.5gplc.com\/products\/honeywell-05701-a-0361-analytical-engineering-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}