{"product_id":"honeywell-04230-a-1001-hand-held-interrogator","title":"Honeywell 04230-A-1001 Hand Held Interrogator","description":"\u003cp\u003eConfigured for field configuration and diagnostic interrogation in Optima, Optima Plus, and Excel gas detection networks, the \u003cstrong\u003eHoneywell 04230-A-1001\u003c\/strong\u003e (\u003cstrong\u003e04230-A-1001\u003c\/strong\u003e SHC-1 Type) handheld interrogator provides direct physical\/electrical execution of communication with field-mounted sensors. The device utilizes 4V0 software to facilitate bidirectional data exchange, allowing for parameter adjustment and status monitoring across compatible hazardous area sensor platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e04230-A-1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBattery-powered operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eStainless Steel ANSI 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIntrinsic Safety (Ex i) Barriers\u003c\/h3\u003e\n\u003cp\u003eThe 04230-A-1001 interrogator is ATEX certified for use in hazardous areas, incorporating stringent intrinsic safety (Ex i) design limits to prevent the discharge of ignition-capable energy into the field circuit. The internal circuitry limits voltage and current to levels that maintain the integrity of the explosive atmosphere classification of the connected sensors. During interrogation, the device must be verified for operational compatibility with the specific barrier ratings of the gas detection loop to prevent circuit overloading or the compromise of hazardous area safety compliance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this interrogator compatible with firmware versions other than 4V0?\u003c\/p\u003e\n\u003cp\u003eA: The 04230-A-1001 is optimized for use with 4V0 software. Attempting to interface with hardware requiring different firmware versions may result in communication handshake errors or data corruption during configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Can this device be used to perform firmware updates on the sensor?\u003c\/p\u003e\n\u003cp\u003eA: This unit functions primarily as a parameter configuration and diagnostic interrogation tool. It does not possess the memory or transmission bandwidth required for full sensor firmware flashing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Handling\u003c\/strong\u003e: Verify the unit's ATEX certification status and compatibility with the local zoning requirements before use in a hazardous environment. Ensure the battery compartment is sealed and undamaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Procedure\u003c\/strong\u003e: Connect the interrogation cable to the sensor interface port before powering on the unit. Avoid forced insertion, which can damage the connector pins and invalidate the intrinsic safety seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e: Do not exceed the specified operating temperature range of 0 deg C to +40 deg C. Prolonged exposure to temperatures outside these limits can result in display degradation and timing errors during data transmission.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCleaning and Storage\u003c\/strong\u003e: Clean the stainless steel housing using non-abrasive cloths. Store the unit in a dry environment with humidity levels maintained below 99% RH to prevent internal component corrosion or long-term storage battery leakage.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52972285231413,"sku":"04230-A-1001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/04230-A-1001.png?v=1780905960","url":"https:\/\/www.5gplc.com\/products\/honeywell-04230-a-1001-hand-held-interrogator","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}