{"product_id":"general-electric-is220pturh1a-primary-turbine-protection-pack","title":"General Electric IS220PTURH1A Primary Turbine Protection Pack","description":"\u003cp\u003eConfigured for primary turbine protection and speed sensing in Mark VIe control systems, the \u003cstrong\u003eGeneral Electric IS220PTURH1A\u003c\/strong\u003e (\u003cstrong\u003eIS220PTURH1A\u003c\/strong\u003e Primary Turbine Protection Pack) provides direct electrical execution of turbine speed acquisition and emergency trip logic. This hardware component serves as the primary PTUR I\/O pack utilized to execute magnetic speed sensor signal processing and overspeed protection across turbine control platform architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PTURH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O pack form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Performance\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Ethernet; Magnetic speed input; Overspeed trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS220PTURH1A interfaces with the TTURH1C terminal board to facilitate high-speed turbine protection sequences. The pack incorporates an onboard processor board, an auxiliary analog acquisition board, and a dedicated turbine control board within its protective housing. It manages two 10\/100 Ethernet ports, ensuring deterministic connectivity to the control system network. The module is engineered with magnetic speed input sensitivity capable of detecting near-zero speed conditions, allowing for accurate zero-speed validation when the turbine has ceased rotation. Firmware flash compatibility is supported via auto-reconfiguration; the controller automatically downloads the baseload, bootloader, and application firmware upon detection of the pack. The processor utilizes median speed signal selection for both speed control loops and principal overspeed trip initiation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the infrared (IR) port on the front of the IS220PTURH1A used for communication?\u003c\/p\u003e\n\u003cp\u003eA: No. The IR receiver port is present on the housing but is not utilized for any functional communication or configuration tasks within the Mark VIe turbine control platform.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS220PTURH1A be hot-swapped while the turbine is running?\u003c\/p\u003e\n\u003cp\u003eA: In a redundant I\/O configuration, the module can be removed, but strict adherence to system-specific safety protocols is required. Because this module performs the principal overspeed trip function, improper removal in a non-redundant system will trigger a turbine shutdown.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Ensure the PTUR pack is securely mounted to the TTURH1C terminal board. Ensure the DC-62 pin connector is fully seated to maintain reliable signal transmission between the pack and the terminal board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetworking\u003c\/strong\u003e: Connect the two 10\/100 Ethernet ports to the designated turbine control IONet switches. Use shielded CAT5e or better cabling to prevent electrical noise from corrupting speed sensing data.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Wiring\u003c\/strong\u003e: Magnetic speed sensors must be connected to the TTURH1C terminal board inputs. Verify that the shield is terminated at the cabinet ground to prevent the introduction of low-level common-mode noise into the frequency-to-voltage conversion circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Inspection\u003c\/strong\u003e: Ensure air circulation holes are not obstructed by cabling or dust accumulation to maintain internal operating temperature within limits. Monitor the front-panel LED indicators for system status and fault alerts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52983885726005,"sku":"ISP220PTURH1A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ISP220PTURH1A.png?v=1781081505","url":"https:\/\/www.5gplc.com\/products\/general-electric-is220pturh1a-primary-turbine-protection-pack","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}