{"product_id":"general-electric-is220paoch1b-analog-output-module","title":"General Electric IS220PAOCH1B Analog Output Module","description":"\u003cp\u003eConfigured for precision signal conversion and loop regulation in Mark VIe distributed control systems, the \u003cstrong\u003eGeneral Electric IS220PAOCH1B\u003c\/strong\u003e (\u003cstrong\u003eIS220PAOCH1B\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution of eight independent current-loop outputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS220PAOCH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.26 cm H x 4.19 cm W x 12.1 cm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 current output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA (up to 900 Ohms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% over -30 deg C to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Network Operations\u003c\/h3\u003e\n\u003cp\u003eThe IS220PAOCH1B utilizes dual RJ45 Ethernet connectors to facilitate deterministic communication within the Mark VIe I\/O network. The module is architected with a common processor board shared across the Mark VIe line, paired with a dedicated analog output acquisition board to handle I\/O density scaling. The firmware flash compatibility allows for seamless integration into existing control racks, supporting high-speed polling and diagnostic packet transmission. The module architecture ensures that all 0-20 mA output signals maintain loop integrity through internal current feedback monitoring, which is mapped back to the controller to verify execution against commanded setpoints.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS220PAOCH1B support hot-swapping in an energized Mark VIe rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the I\/O pack is designed for removal and insertion while the system is powered, provided that the associated terminal board connection is handled to prevent unexpected output state changes.\u003c\/p\u003e\n\u003cp\u003eQ: How is the current feedback verified for each channel?\u003c\/p\u003e\n\u003cp\u003eA: Each of the eight output channels includes an internal analog-to-digital converter (ADC) that monitors the actual current loop feedback, providing high-fidelity loop health data to the host controller via the Ethernet interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Coupling:\u003c\/strong\u003e The module uses a DC-37 pin connector for direct mating to the corresponding terminal board. Ensure the connector is fully seated and the retention hardware is secured to maintain mechanical stability and signal integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e Utilize the dual RJ45 ports to establish redundant connections to the I\/O Ethernet networks. Ensure that the cables are rated for industrial environments to minimize signal latency and packet loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Termination:\u003c\/strong\u003e Use the specified three-pin connector for power input. Verify the supply voltage at the pin terminals before engaging the module to prevent damage to the internal power regulation circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Verification:\u003c\/strong\u003e Upon installation, check the local diagnostic LED indicators. For advanced troubleshooting, utilize the infrared port to interface with local diagnostic tools if HMI-based status reporting is unavailable.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52988757541173,"sku":"IS220PAOCH1B","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS220PAOCH1B.png?v=1781161505","url":"https:\/\/www.5gplc.com\/products\/general-electric-is220paoch1b-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}