{"product_id":"general-electric-is200tbcis2ccd-mark-vi-control-circuit-board","title":"General Electric IS200TBCIS2CCD Mark VI Control Circuit Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200TBCIS2CCD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core Control Circuit Board within General Electric's Speedtronic Mark VI control family. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal board manages the sophisticated logic and control functions required for utility-scale gas and steam turbines. It facilitates high-speed signal processing between field devices and the controller, ensuring deterministic execution of turbine governing, sequencing, and protection algorithms. By integrating 32 dedicated I\/O points and multi-protocol communication, it maintains precise operational control under the most demanding industrial loads.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBCIS2CCD utilizes a high-density PCB layout optimized for thermal stability and high-speed data throughput.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI (Speedtronic)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200TBCIS2CCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput\/Output Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Watts (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet, RS-232, and proprietary interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e340 mm x 216 mm x 55 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg (2.2 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board operates across an industry-leading temperature range of -40°C to +85°C. This wide thermal envelope allows the board to maintain timing accuracy in unconditioned control rooms or remote skids located in extreme climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Communication Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard interface supports Ethernet for high-speed plant-level networking and RS-232 for localized diagnostics and configuration. This dual-path connectivity enables seamless integration with both modern DCS networks and legacy maintenance tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Power Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board consumes only 10 Watts of power during full-load operation. This efficiency reduces the heat load within the Mark VI rack, preventing thermal stress on neighboring components and extending the overall MTBF (Mean Time Between Failures) of the control suite.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThirty-two I\/O points allow for the consolidation of multiple turbine auxiliary functions onto a single board. This density reduces the required number of rack slots and simplifies the backplane wiring architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this IS200TBCIS2CCD unit a refurbished or used board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this product is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal GE factory stock. It remains in its original protective anti-static packaging and has never been installed in a field environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify if this \"S2CCD\" revision is compatible with my system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S2CCD\" suffix indicates a specific hardware revision and functional coating level. You must verify that your Mark VI configuration files (typically managed in Toolbox) support this specific revision to ensure proper driver initialization and diagnostic reporting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary mounting requirements for this circuit board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200TBCIS2CCD slides directly into the Mark VI VME-style rack. You must ensure the ejector tabs lock securely into the rack frame to maintain consistent electrical contact with the backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board require manual calibration for its I\/O points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mark VI system typically handles calibration via software; however, we recommend verifying the 24VDC supply stability at the rack level before commissioning to ensure the board's internal power regulators operate within their peak efficiency range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52525603979573,"sku":"IS200TBCIS2CCD","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200TBCIS2CCD.jpg?v=1775102618","url":"https:\/\/www.5gplc.com\/products\/general-electric-is200tbcis2ccd-mark-vi-control-circuit-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}