{"product_id":"general-electric-is200jpdfg1a-dc-power-distribution-module","title":"General Electric IS200JPDFG1A DC Power Distribution Module","description":"\u003cp\u003eConfigured for power distribution and ground fault monitoring in Mark VIe control architectures, the \u003cstrong\u003eGE IS200JPDFG1A\u003c\/strong\u003e (\u003cstrong\u003eIS200JPDFG1A\u003c\/strong\u003e DC Power Distribution Module) provides direct physical and electrical execution of redundant 125 VDC power routing and bus status management.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 99.9521%; height: 166.666px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003cth style=\"width: 29.9207%; height: 19.5833px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 67.2071%; height: 19.5833px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003eIS200JPDFG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 10px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 10px;\"\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003eStandard PCB assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003eMark VIe standard form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003eIndustrial rated range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003e125 VDC (Redundant inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 29.9207%; height: 19.5833px;\"\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 67.2071%; height: 19.5833px;\"\u003e3 x Non-switched, 6 x Switched fused outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200JPDFG1A integrates into the Mark VIe control platform to ensure power distribution integrity across the system backplane. The module utilizes deterministic communication via the PPDA I\/O pack to report bus magnitude, ground faults, and AC voltage presence, which maintains synchronized monitoring of power health. Firmware flash compatibility is aligned with system-wide power management protocols to ensure hardware revision synchronization. The module supports I\/O density scaling by providing a unified interface for both battery-backed power and converted DC power, ensuring high-reliability power delivery to downstream control modules. The board's architecture facilitates efficient I\/O signal distribution, ensuring that power status feedback remains compliant with deterministic network timing requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200JPDFG1A support hot-swapping under load?\u003c\/p\u003e\n\u003cp\u003eA: No. Replacement of the power distribution board requires full isolation of the 125 VDC battery inputs and the removal of all fused output loads to prevent electrical damage during handling.\u003c\/p\u003e\n\u003cp\u003eQ: How does the JPDF module handle redundant power inputs?\u003c\/p\u003e\n\u003cp\u003eA: The board is designed to operate with any combination of one or more active 125 VDC power inputs, performing automatic power combination to provide a stable DC source for the control system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board in the chassis using the standard mounting hardware. Ensure the module is seated to maintain proper electrical contact with the power distribution backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the redundant 125 VDC battery inputs to the designated terminal board. Utilize a 30 A circuit breaker and appropriate line filter as specified in the installation documentation to protect the input stage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e The JPDF operates on a floating DC bus centered on Earth. Ensure the system ground reference is correctly established to allow for accurate ground fault detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitoring:\u003c\/strong\u003e Connect the PPDA I\/O pack to the module to enable status feedback monitoring. Verify that the system software correctly identifies the bus magnitude and ground fault status after installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit Verification:\u003c\/strong\u003e Post-installation, inspect each fused branch circuit to verify the presence of output power. Ensure all fuses are correctly rated and seated to prevent operational failure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52938056532277,"sku":"IS200JPDFG1A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200JPDFG1A.png?v=1780043933","url":"https:\/\/www.5gplc.com\/products\/general-electric-is200jpdfg1a-dc-power-distribution-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}