{"product_id":"general-electric-is200jpdeg1aaa-dc-battery-power-distribution-board","title":"General Electric IS200JPDEG1AAA DC Battery Power Distribution Board","description":"\u003cp\u003eConfigured for power regulation and routing in Mark VIe control architectures, the \u003cstrong\u003eGE IS200JPDEG1AAA\u003c\/strong\u003e (\u003cstrong\u003eIS200JPDEG1AAA\u003c\/strong\u003e DC Battery Power Distribution Board) provides direct physical and electrical execution of DC bus management and load distribution within Speedtronic turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200JPDEG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eN\/A (Standard PCB assembly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.51 cm x 17.08 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200JPDEG1AAA facilitates distribution for floating DC bus architectures, ensuring stability for downstream terminal boards and system loads. The board integrates into the PDM (Power Distribution Module) system by providing essential feedback through the PPDA I\/O pack. To maintain deterministic system health, the board utilizes resistive grounding to center the DC bus, allowing the host controller to detect ground faults with high precision. While the module supports 24 VDC or 48 VDC operation, it serves primarily as a passive distribution interface and does not supply bulk power to high-wattage I\/O pack control units, ensuring backplane bus communication velocity remains isolated from transient power fluctuations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this board be used to power 500 W bulk power supplies?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200JPDEG1AAA design is optimized for distribution to terminal boards and local loads. It is current-limited by conventional board construction and should not be used to drive bulk power supplies for I\/O pack control power.\u003c\/p\u003e\n\u003cp\u003eQ: How does the board handle system ground faults?\u003c\/p\u003e\n\u003cp\u003eA: The board employs a floating DC bus centered on earth via integrated resistors. It provides voltage feedback signals to the PPDA I\/O pack, enabling the turbine control system to monitor for and identify system ground faults in real-time.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board onto a standard DIN rail within the designated PDM cabinet enclosure. Ensure the mounting surface is clean and electrically bonded to the cabinet chassis for proper grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect dual power supply inputs to the designated terminals. Use appropriate wire gauges to accommodate the 18-32 VDC range and ensure all connections are torqued to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify the integrity of the resistive grounding circuit. The board must be connected to a known earth ground to maintain the reference point for ground fault detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration:\u003c\/strong\u003e Ensure the board communicates correctly with the PPDA I\/O pack. Perform a software check via the turbine control interface to verify that feedback signals are correctly mapped and reporting nominal status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain the cabinet ambient temperature between 0 and 60 deg C. Ensure the surrounding area is free from conductive dust or moisture that could compromise the 1500 V input isolation integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52937745137973,"sku":"IS200JPDEG1AAA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200JPDEG1AAA.png?v=1780036322","url":"https:\/\/www.5gplc.com\/products\/general-electric-is200jpdeg1aaa-dc-battery-power-distribution-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}