{"product_id":"general-electric-is200aepah1a-optional-auxiliary-board","title":"General Electric IS200AEPAH1A Optional Auxiliary Board","description":"\u003cp\u003eConfigured for auxiliary drive control and signal routing in industrial drive systems, the \u003cstrong\u003eGE IS200AEPAH1A\u003c\/strong\u003e (\u003cstrong\u003eIS200AEPAH1A\u003c\/strong\u003e Optional Auxiliary Board) provides direct physical and electrical execution of multi-channel I\/O signal conditioning and relay logic activation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard PCB assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13 in x 7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEPAH1A serves as a high-density auxiliary interface module within the drive control architecture, designed to optimize backplane bus communication velocity for subordinate signal processing tasks. The module leverages standardized bus protocols to ensure synchronized data exchange between the primary drive controller and field-level I\/O. Firmware flash compatibility is managed through the host system software to ensure hardware revision alignment. The board facilitates I\/O density scaling by integrating mixed-signal capabilities—including 20 discrete inputs and 8 relay outputs—onto a single interface, enabling the control system to expand its monitoring and command capacity without increasing the rack footprint.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module capable of hot-swap operation in an active drive cabinet?\u003c\/p\u003e\n\u003cp\u003eA: No. Installation and removal must be performed while the control rack is de-energized to prevent electrical shorts and communication bus interference with adjacent modules.\u003c\/p\u003e\n\u003cp\u003eQ: Are the 8 analog input channels isolated from the relay output circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The board design requires proper physical isolation and shielding during installation to prevent electromagnetic interference from relay switching transients affecting the integrity of the analog input signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the board using the designated chassis mounting points. Ensure the PCB is properly seated to maintain mechanical stability and correct alignment with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded, twisted-pair cabling for all analog input channels to preserve signal accuracy. Terminate cable shields at the designated cabinet grounding rail to suppress electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Logic:\u003c\/strong\u003e Verify that external load currents for the 8 relay outputs do not exceed the board's rated switching capacity. Utilize external suppression diodes if switching inductive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Operate the module within a temperature range of 0 deg C to 60 deg C. Ensure that cabinet cooling fans are operational to prevent the buildup of heat around the surface-mount components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Post-installation, perform a diagnostic I\/O verification in the control software to confirm that all 20 discrete inputs and 8 relay outputs are mapped correctly to the controller logic.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52937963536693,"sku":"IS200AEPAH1A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200AEPAH1AFD_3e84b95c-d08b-4916-bdc4-54182c8c8e2b.png?v=1780041225","url":"https:\/\/www.5gplc.com\/products\/general-electric-is200aepah1a-optional-auxiliary-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}