{"product_id":"general-electric-ds200rtbag2ahc-relay-terminal-board","title":"General Electric DS200RTBAG2AHC Relay Terminal Board","description":"\u003cp\u003eConfigured for relay-based signal interfacing within Mark V Speedtronic control systems, the \u003cstrong\u003eGE DS200RTBAG2AHC\u003c\/strong\u003e (\u003cstrong\u003eDS200RTBAG2\u003c\/strong\u003e Relay Terminal Board) provides direct physical electrical switching for LAN and remote I\/O control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200RTBAG2AHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (coil voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Components\u003c\/td\u003e\n\u003ctd\u003e7 DPDT (Form-C) relays, 3 4PDT relays, 10 MOV surge protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DS200RTBAG2AHC functions as a passive interface module, requiring no firmware flash compatibility as it contains no logic-based software. Operational parameters are governed by board-level jumper configurations via berg-type jumper pins, which must be aligned with site-specific I\/O requirements to ensure deterministic relay state execution. Backplane bus communication velocity is managed through the host interface, while the onboard diagnostic lamps provide real-time status indication of relay coil activation. The board utilizes MOV protection (130 V AC) for each relay to mitigate surge-induced damage, ensuring the module maintains its signal-switching integrity under inductive loading conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the MOVs on the relay terminal board field-replaceable?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each of the ten relays is protected by a 130 V AC metal oxide varistor (MOV). If a surge event occurs, these components are designed to be removed and replaced individually to restore relay protection without requiring a full board replacement.\u003c\/p\u003e\n\u003cp\u003eQ: How do I select the correct relay terminal board for my application?\u003c\/p\u003e\n\u003cp\u003eA: Selection is based on required coil voltage. The DS200RTBAG2AHC is rated for 24 VDC. For 110 VDC applications, specify the RTBAG1 board; for 115 VAC applications, specify the RTBAG3 board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Protection\u003c\/strong\u003e: Ensure that the MOVs are properly seated and intact prior to power-up. Damaged MOVs can lead to premature failure of the DPDT or 4PDT relay contacts due to high-voltage transients during inductive load switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Configuration\u003c\/strong\u003e: Verify all berg-type jumper pin settings against the installation manual before initial energization. Incorrect jumper placement can lead to improper relay logic or feedback failures on the LAN\/remote I\/O circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: The board features two stab connectors, one 16-pin connector, and one 2-pin inter-board connector. Ensure these are free of debris and fully engaged to prevent intermittent signal paths that could cause relay \"chatter\" or false state reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: When terminating field wires, ensure proper cable management to avoid mechanical stress on the PCB. Verify that the cabinet ground connection is robust, as this board serves as a centralized relay termination point for sensitive control signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52991706956085,"sku":"DS200RTBAG2AHC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200RTBAG2AHC.png?v=1781248322","url":"https:\/\/www.5gplc.com\/products\/general-electric-ds200rtbag2ahc-relay-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}