{"product_id":"general-electric-151x207ba10sa01-battery-charger-sub-assembly","title":"General Electric 151X207BA10SA01 Battery Charger Sub-Assembly","description":"\u003cp\u003eConfigured for high-performance DC power buffering in industrial control networks, the \u003cstrong\u003eGE 151X207BA10SA01\u003c\/strong\u003e (\u003cstrong\u003e151X207BA10SA01\u003c\/strong\u003e Battery Charger Sub-Assembly) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e151X207BA10SA01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 mm x 90 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 - +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Load Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Protection\u003c\/td\u003e\n\u003ctd\u003eOvercurrent and short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSpecific GE Fanuc control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Power Link Execution\u003c\/h3\u003e\n\u003cp\u003eThe hardware subsystem regulates direct current delivery to support downstream logic backup configurations. Charging paths continuously monitor output thresholds to trigger overcurrent and short-circuit protective loops when baseline parameters are breached. To ensure deterministic power failure detection profiles across local backplane grids, systemic system parameter updates must be matched with exact firmware flash compatibility rules implemented across peripheral controller nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 151X207BA10SA01 assembly allow hot-swapping while under active source voltage?\u003c\/p\u003e\n\u003cp\u003eA: No. The terminal contacts do not possess sequential grounding traces or integrated pre-charge power arcs. De-energize the primary 24 VDC supply line before replacement to avoid transient hardware stress.\u003c\/p\u003e\n\u003cp\u003eQ: How does the integrated short-circuit protection function reset post-fault remediation?\u003c\/p\u003e\n\u003cp\u003eA: The circuit protection cuts output drive upon sensing zero-impedance loads. Once the external fault on the 24 VDC path is removed, internal logic initiates automatic recovery loops to resume normal 2 A charging profiles.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Orientation Layout:\u003c\/strong\u003e Mount the compact sub-assembly securely inside the enclosure chassis, ensuring vertical alignment to optimize passive thermal dispersion profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Terminal Wiring Execution:\u003c\/strong\u003e Secure the 24 VDC input and output connections into the designated wire block pins using specified strip lengths to prevent loose-wire resistance heat buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Common Earthing:\u003c\/strong\u003e Bridge the frame ground point directly to the main cabinet low-impedance copper ground plane to minimize high-frequency electronic noise generation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53114555007285,"sku":"151X207BA10SA01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/151X207BA10SA01.png?v=1783672312","url":"https:\/\/www.5gplc.com\/products\/general-electric-151x207ba10sa01-battery-charger-sub-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}