{"product_id":"ge-vmivme-7750-734-vmebus-module","title":"GE VMIVME-7750-734 VMEbus Module","description":"\u003cp\u003eConfigured for digital-to-analog signal conversion in VMEbus systems, the \u003cstrong\u003eGE VMIVME-7750-734\u003c\/strong\u003e (\u003cstrong\u003eVMIVME-7750\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVMIVME-7750-734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard VME Slot Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot VMEbus Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 - 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-fed via VMEbus Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e32 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eVMEbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage\/Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eHigh Linearity Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Channel Segregation and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe VMEbus architecture utilizes dedicated addressing lines to execute high-speed parallel data transfers across the backplane. The module accommodates high I\/O density scaling by mapping 32 independent channels within a single-slot VME form factor. This high density requires precise register allocation and internal crosstalk suppression circuits to prevent signal degradation during concurrent high-velocity channel updates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping within an active VMEbus chassis?\u003c\/p\u003e\n\u003cp\u003eA: No. The VMEbus standard utilized by this module lacks live-insertion pin sequencing. Removing or inserting the hardware while the backplane is energized will cause electrical transients, disrupting bus communications and causing system faults.\u003c\/p\u003e\n\u003cp\u003eQ: How is channel ground loops avoided across the 32 output terminals?\u003c\/p\u003e\n\u003cp\u003eA: The 32 output channels share a common ground reference linked to the VMEbus power return line. External field wiring must maintain isolated loops or use external signal conditioners to prevent common-mode ground loop currents from degrading the 12 bits resolution accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Positioning:\u003c\/strong\u003e Turn off all chassis power before sliding the module into the VME backplane slot guides. Verify that the top and bottom mechanical injector\/ejector handles lock fully to guarantee pin mating engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Compliance:\u003c\/strong\u003e Ground the VME chassis enclosure frame directly to a low-impedance master ground bus to minimize static interference and protect the 12 bits digital-to-analog converters from high-frequency noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding:\u003c\/strong\u003e Connect all 32 analog signal output lines using shielded twisted-pair cables. Terminate the shield at the cabinet entry gland plate and avoid routing parallel to high-voltage AC conductors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53113884803381,"sku":"VMIVME-7750-734","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VMIVME-7750-734.png?v=1783663104","url":"https:\/\/www.5gplc.com\/products\/ge-vmivme-7750-734-vmebus-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}