{"product_id":"ge-vmivme-2170a-332-102170-110-digital-output-board","title":"GE VMIVME-2170A 332-102170-110 Digital Output Board","description":"\u003cp\u003eConfigured for discrete state actuation in VMEbus networks, the \u003cstrong\u003eGE VMIVME-2170A 332-102170-110\u003c\/strong\u003e (\u003cstrong\u003eVMIVME-2170A\u003c\/strong\u003e Digital Output Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVMIVME-2170A 332-102170-110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Double Eurocard Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDouble Eurocard Format with Front Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 - 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eVMEbus Backplane Rails Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Count\u003c\/td\u003e\n\u003ctd\u003e32 optically isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA or 300 mA options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Tolerance\u003c\/td\u003e\n\u003ctd\u003eUp to 30 VDC in normal mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1 kV sustained \/ 6 kV pulsed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Addressing\u003c\/td\u003e\n\u003ctd\u003e14-bit board selection via onboard DIP switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Width\u003c\/td\u003e\n\u003ctd\u003e8-bit or 16-bit parallel transfers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Register Constraints\u003c\/h3\u003e\n\u003cp\u003eThe module maps its 32 discrete output channels into the VMEbus system space using a 14-bit base address chosen by hardware DIP switches. Data write cycles support 8-bit or 16-bit transfer widths over the backplane bus interface. To prevent bus timeouts and maximize data throughput, internal logic registers update output states instantaneously. Mismatches in backplane timing parameters or firmware flash compatibility will interrupt data synchronization, forcing a master processor bus error.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the VMIVME2170A card be plugged or unplugged while the VME chassis is live?\u003c\/p\u003e\n\u003cp\u003eA: No. The parallel backplane J1\/J2 architecture does not incorporate pre-charging pins or staggered ground trace structures to handle live insertion. Hot-swapping the hardware will generate electrical transients that can damage the logic arrays.\u003c\/p\u003e\n\u003cp\u003eQ: How do the two distinct output drive options (2.5 mA and 300 mA) alter terminal allocation?\u003c\/p\u003e\n\u003cp\u003eA: The drive capacity depends on the physical trace layout and internal optocoupler configurations chosen during component layout setup. Load currents exceeding 300 mA will trigger thermal faults and destroy the affected channel isolation barrier.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Address Assignment:\u003c\/strong\u003e Configure the 14-bit address space via the onboard DIP switches before inserting the card into the rack. Cross-reference the system map to prevent address overlap with other VME modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Engagement:\u003c\/strong\u003e Align the card rails with the Double Eurocard guides. Push smoothly until the connectors sit inside the backplane receptacle. Fasten the top and bottom front panel screws to ensure solid structural grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Shielding Practices:\u003c\/strong\u003e Wire the 32 discrete outputs using shielded cables separated from alternating current (AC) power grids. Attach cable shields to a single grounding bar within the main enclosure to eliminate ground loop currents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53114066993461,"sku":"VMIVME-2170A 332-102170-110","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VMIVME2170A332-102170-110.png?v=1783666245","url":"https:\/\/www.5gplc.com\/products\/ge-vmivme-2170a-332-102170-110-digital-output-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}