{"product_id":"ge-st-2328-rsti-series-digital-output-module","title":"GE ST-2328 RSTi Series Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE ST-2328\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eST-2328\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for discrete state actuation within RSTi Series network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eST-2328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RSTi Slice Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 - 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic Rail Dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e8 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive logic (Source configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail interface terminal base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Deterministic Networks Integration\u003c\/h3\u003e\n\u003cp\u003eThe module manages 8 discrete positive-logic output channels within a compact slice footprint to optimize I\/O density scaling inside control enclosures. The internal circuitry drives external loads up to 0.5 A per point at a nominal 24 VDC rating. State data transfers from the master controller cross the network adapter over Profinet \/ EtherNet\/IP deterministic networks, updating the local hardware image registers. Proper execution across the slice backplane depends directly on verifying firmware flash compatibility with the upstream bus coupler.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ST-2328 module support live extraction or hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The parallel backplane connections on the RSTi platform do not possess staggered circuit layouts or pre-charge isolation layers. Removing the slice while the bus terminal base is energized will induce localized electrical faults and interrupt network data cycles.\u003c\/p\u003e\n\u003cp\u003eQ: How is the positive logic structure reference wired on the field terminal side?\u003c\/p\u003e\n\u003cp\u003eA: The sourcing channels supply 24 VDC directly from the internal power rail to the field load when activated. External field actuators must have their return lines terminated directly to the common negative DC reference rail of the supply circuit.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting Sequence:\u003c\/strong\u003e Align the module side interlocking guides with the adjacent RSTi unit. Press downward firmly onto the DIN rail until the integrated mechanical slide lock snaps completely into position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation Rules:\u003c\/strong\u003e Route the 24 VDC discrete output paths through isolated terminal wireways separated from alternating current (AC) distribution lines to prevent capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Power Distribution:\u003c\/strong\u003e Connect the auxiliary 24 VDC field power supply directly to the corresponding terminal base power distribution contacts to ensure the 0.5 A per channel drive limit is maintained under full load conditions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53114230178101,"sku":"ST-2328","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ST-23281.png?v=1783668771","url":"https:\/\/www.5gplc.com\/products\/ge-st-2328-rsti-series-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}