{"product_id":"ge-is200vrtdh1d-mark-vie-rtd-input-module","title":"GE IS200VRTDH1D Mark VIe RTD Input Module","description":"\u003cp\u003eConfigured for high-precision temperature sensing in Mark VIe control systems, the \u003cstrong\u003eGE IS200VRTDH1D\u003c\/strong\u003e (\u003cstrong\u003eIS200VRTDH1DAB\u003c\/strong\u003e RTD Input Module) provides direct physical\/electrical execution. This board performs excitation of Resistance Temperature Devices (RTDs) and digitizes resulting analog signals, transferring the converted temperature data across the VME backplane to the VCMI and host controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VRTDH1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe PCB form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on RTD excitation load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eRTD (Resistance Temperature Device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drives Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe VRTD module utilizes active sensing circuits to monitor RTD continuity, automatically flagging open or short-circuit conditions as out-of-range values. To maintain input integrity, the module isolates out-of-range channels from the scan list to prevent potential adverse interference with valid input signals. Reinstatement of faulted channels occurs automatically at 20-second intervals upon signal normalization, or via manual intervention. Integration requires strict adherence to backplane bus communication velocity settings, and users must ensure firmware flash compatibility when upgrading or replacing modules to maintain deterministic temperature data throughput.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200VRTDH1DAB backward compatible with earlier versions of the VRTD board?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The IS200VRTDH1DAB maintains backward compatibility with the first two revisions of the VRTD series, allowing for seamless integration in existing Mark VIe controller environments.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle sensor fault detection?\u003c\/p\u003e\n\u003cp\u003eA: The VRTD module continuously monitors RTD input values against predefined hardware limits. If a value falls outside these limits, the channel is marked as faulted and excluded from active scanning. The module performs a periodic re-scan of these faulted channels every 20 seconds to determine if the sensor has returned to operational range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVME Backplane Seating\u003c\/strong\u003e: De-energize the Mark VIe cabinet prior to installation. Align the module with the VME rack guides and ensure the backplane connector is fully seated to guarantee secure electrical communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Wiring\u003c\/strong\u003e: Connect RTD sensors to the associated terminal board. Use shielded, twisted-pair cabling to minimize noise and ensure high-accuracy temperature readings. Terminate shields at the cabinet ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Integrity\u003c\/strong\u003e: The module is treated with conformal coating. Handle the board by the edges to prevent physical damage to the coating. Avoid exposure to high-humidity or chemically aggressive environments without ensuring the cabinet is sealed to NEMA\/IP standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Verification\u003c\/strong\u003e: After physical installation, confirm the module revision level through the controller interface. If utilizing backward compatibility with earlier revisions, ensure the application software is configured correctly to recognize the VRTD module type.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52948767572277,"sku":"IS200VRTDH1D","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200VRTDH1D.png?v=1780296580","url":"https:\/\/www.5gplc.com\/products\/ge-is200vrtdh1d-mark-vie-rtd-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}