{"product_id":"ge-is200tvibh2bbb-mark-vi-vibration-terminal-board","title":"GE IS200TVIBH2BBB Mark VI Vibration Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS200TVIBH2BBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibration Terminal Board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the General Electric Speedtronic Mark VI control system. This board provides the critical physical interface for machinery protection sensors, capturing essential data to prevent mechanical failure. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your industrial assets operate with factory-certified monitoring accuracy. By centralizing probe inputs and distributing power, the IS200TVIBH2BBB forms the backbone of real-time vibration, displacement, and velocity sensing for large-scale turbines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200TVIBH2BBB utilizes a high-density connection layout designed for the rigorous electrical requirements of turbine decks.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark VI Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Terminal Board (TVIB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProbe Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 14 Bently Nevada Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVVIB (Vibration Input Vector Board)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e23.8 cm (H) x 8.6 cm (W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States of America (USA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Bently Nevada Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board accepts direct wiring from up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14 Bently Nevada probes\u003c\/strong\u003e. This consolidation eliminates the need for external junction boxes or intermediate signal conditioners, significantly reducing the complexity of your turbine's instrumentation wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Vector Board Interfacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TVIB board routes signals from two specific probes directly to the VVIB (Vibration Input Vector Board). This pathway allows the system to digitize displacement and velocity data for high-speed transmission over the VME bus to the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Conditioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard circuitry provides a stable power supply to field sensors and processes raw analog inputs into actionable alarm and trip logic. This local hardware-level processing ensures the system triggers safety protocols instantly during critical vibration events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for harsh industrial climates, the board maintains full functional integrity from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-30°C to +65°C\u003c\/strong\u003e. This thermal range ensures reliability in unconditioned control cabinets or remote enclosures located in diverse geographic regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Vertical Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe narrow 8.6 cm profile maximizes cabinet rail density. This compact footprint allows engineers to install multiple monitoring boards side-by-side, scaling the system’s protection capabilities without requiring additional enclosure space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IS200TVIBH2BBB interface with different types of sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The board primarily handles proximity probes for displacement and vibration monitoring. When paired with the VVIB board, it also processes velocity signals, providing a comprehensive view of the machine's mechanical health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board support redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200TVIBH2BBB functions within the Mark VI architecture, which supports various redundancy levels. In high-reliability applications, technicians often deploy multiple boards to ensure continuous monitoring during a single hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary installation requirements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must mount the board vertically to optimize heat dissipation. Ensure all 14 probe inputs follow the specific wiring diagrams for the Mark VI system to maintain signal polarity and power distribution accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm this is a \"Brand New\" unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery IS200TVIBH2BBB we ship arrives in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoriginal factory packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith intact GE serial numbers and the \"Made in USA\" designation, guaranteeing the hardware has zero previous service hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52834627977525,"sku":"IS200TVIBH2BBB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200TVIBH2BBB.png?v=1778126346","url":"https:\/\/www.5gplc.com\/products\/ge-is200tvibh2bbb-mark-vi-vibration-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}