{"product_id":"ge-is200tbcih1b-mark-vie-contact-input-terminal-board","title":"GE IS200TBCIH1B Mark VIe Contact Input Terminal Board","description":"\u003cp\u003eConfigured for discrete signal acquisition in Mark VIe distributed control systems, the \u003cstrong\u003eGE IS200TBCIH1B\u003c\/strong\u003e (\u003cstrong\u003eIS200TBCIH1B\u003c\/strong\u003e Contact Input Terminal Board) provides direct physical\/electrical execution. This terminal board facilitates the connection of 24 dry-contact inputs, utilizing onboard DC excitation and integrated noise suppression circuitry to protect against surge and high-frequency interference.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBCIH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe terminal board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDC powered for contact excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e24 Dry-contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBCIH1B supports direct integration with PDIA I\/O packs within the Mark VIe architecture. The terminal board supports configurations using one, two, or three PDIA packs to facilitate simplex or redundant system topologies. Integration with the host processor relies on consistent backplane bus communication velocity; users must ensure that firmware flash compatibility between the PDIA I\/O packs and the VCCC\/VCRC processor boards is maintained to prevent signal polling errors. The board is designed to interface with the VME rack infrastructure via standardized molded cable assemblies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200TBCIH1B compatible with both Mark VI and Mark VIe systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The TBCI series boards are designed for functional compatibility across both Mark VI and Mark VIe platforms, supporting integration into various distributed control architectures.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the noise suppression circuitry on this board?\u003c\/p\u003e\n\u003cp\u003eA: The integrated circuitry serves to mitigate high-frequency noise and voltage surges at the contact inputs, ensuring the integrity of the dry-contact signals before they are processed by the I\/O packs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Connection\u003c\/strong\u003e: Connect external field devices to the two integrated barrier-type terminal blocks. Ensure proper torque is applied to terminal screws to maintain low-impedance connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Pack Seating\u003c\/strong\u003e: When installing PDIA I\/O packs onto the terminal board, ensure mechanical alignment with the JT1 connector to prevent pin damage and ensure robust electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Ensure the terminal board chassis is securely bonded to the control cabinet ground. Route input signal wiring away from high-power AC lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling\u003c\/strong\u003e: Utilize molded cables to interface the terminal board with the VME rack. Ensure that cable lengths do not exceed recommended limits to avoid signal degradation or timing delays in the control loop.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52948705837365,"sku":"IS200TBCIH1B","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200TBCIH1BBC1_a54cc5d1-eef8-4469-b45d-89471a2cbe8e.png?v=1780295547","url":"https:\/\/www.5gplc.com\/products\/ge-is200tbcih1b-mark-vie-contact-input-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}