{"product_id":"ge-is200tbais1c-mark-vie-analog-input-output-terminal-board","title":"GE IS200TBAIS1C Mark VIe Analog Input\/Output Terminal Board","description":"\u003cp\u003eConfigured for analog signal processing in Mark VIe safety-integrated systems, the \u003cstrong\u003eGE IS200TBAIS1C\u003c\/strong\u003e (\u003cstrong\u003eIS200TBAIS1C\u003c\/strong\u003e Analog Input\/Output Terminal Board) provides direct physical\/electrical execution. This terminal board supports both simplex and triple modular redundancy (TMR) configurations, managing thermocouple, current loop, and voltage signals while facilitating precise current regulation through integrated shunt measurement circuitry.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBAIS1C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe terminal board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on connected I\/O loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003e3 x DC-37 pin I\/O processor connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy (TMR) and Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBAIS1C is engineered for safety-certified applications within the Mark VIeS SIS environment. In TMR 2oo3 configurations, the terminal board enables signal fanning, where inputs are distributed across the R, S, and T control channels. The board utilizes an integrated measuring shunt to aggregate current from triple-connected output drivers, providing a composite signal to the I\/O processors for accurate setpoint regulation. The design enforces fail-safe state execution, ensuring that in the event of an I\/O processor discrepancy, the voter logic maintains the safety-critical state. Note that the 200 mA output option is restricted in YAIC-based SIS applications to ensure compliance with certified safety parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200TBAIS1C compatible with simplex application topologies?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board utilizes a dedicated single connector (R1) for simplex applications, while all three DC-37 pin connectors are utilized for TMR configurations to support redundant processing.\u003c\/p\u003e\n\u003cp\u003eQ: How is output current handled in TMR mode?\u003c\/p\u003e\n\u003cp\u003eA: In TMR mode, the terminal board aggregates the currents from the three connected output drivers. An onboard measuring shunt calculates the total current, which is then fed back to the I\/O processors to ensure precise regulation to the commanded setpoint.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Cabling\u003c\/strong\u003e: Connect I\/O processors to the three DC-37 pin ports. For simplex setups, ensure the R1 port is utilized. For TMR, ensure cabling from all three processors (R, S, T) is verified against the system wiring schematic to prevent signal phase or addressing errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: To maintain safety certification integrity, land all cable shields on the designated terminal board grounding points. Minimize path impedance to the system common earth ground to avoid noise-induced errors in analog measurement circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Block Torque\u003c\/strong\u003e: Apply proper torque to the barrier-style terminal blocks when landing field wiring. Loose connections can introduce resistive fluctuations, causing instability in current-loop feedback signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Considerations\u003c\/strong\u003e: Ensure the installation environment remains within rated limits. Avoid proximity to high-frequency power switching equipment to prevent EMI coupling into sensitive low-level analog inputs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52948941111605,"sku":"IS200TBAIS1C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200TBAIS1C__2.png?v=1780299043","url":"https:\/\/www.5gplc.com\/products\/ge-is200tbais1c-mark-vie-analog-input-output-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}