{"product_id":"ge-is200stcih4a-mark-vie-simplex-contact-input-board","title":"GE IS200STCIH4A Mark VIe Simplex Contact Input Board","description":"\u003cp\u003eConfigured for discrete signal acquisition in Mark VIe distributed control systems, the \u003cstrong\u003eGE IS200STCIH4A\u003c\/strong\u003e (\u003cstrong\u003eIS200STCIH4A\u003c\/strong\u003e Simplex Contact Input Board) provides direct physical\/electrical execution. This terminal board processes 48 VDC discrete inputs and interfaces with the IS230STCIH4A module to facilitate contact state monitoring within simplex system topologies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STCIH4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe terminal board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on discrete input load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or flat mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drives Technical Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS200STCIH4A serves as the physical termination point for contact inputs, operating in conjunction with one PDIA I\/O pack. The board architecture supports simplex system configurations, ensuring deterministic signal state capture via the associated I\/O pack. Proper system operation requires validated firmware flash compatibility between the PDIA I\/O pack and the control processor to maintain accurate I\/O image mapping. I\/O density scaling is constrained by the physical capacity of the simplex board; users must ensure that discrete input common and signal lines are routed to provide adequate galvanic separation and minimize signal crosstalk across the board.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200STCIH4A suitable for redundant (TMR) applications?\u003c\/p\u003e\n\u003cp\u003eA: No. The IS200STCIH4A is specifically designed for simplex system configurations. Redundant applications require different terminal board hardware variants compatible with TMR-capable I\/O packs.\u003c\/p\u003e\n\u003cp\u003eQ: Can this board be used for signal voltages other than 48 VDC?\u003c\/p\u003e\n\u003cp\u003eA: No. The board is rated for 48 VDC discrete input operation. Connecting higher or lower voltage levels may lead to incorrect state detection or hardware damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: The board supports both DIN-rail and flat surface mounting. For DIN-rail applications, ensure the mounting hardware is securely engaged. For flat mounting, use the provided chassis standoffs to ensure adequate clearance and prevent electrical shorts between the board trace side and the enclosure backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Connect field discrete inputs to the barrier-type terminal blocks. Ensure wire gauge is appropriate for the terminal rating and that all connections are torqued to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Bond the terminal board chassis to a common earth ground point. This is necessary to maintain signal reference integrity and provide a path for discharge of surge transients suppressed by the board circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: The board is provided with conformal coating. Handle the assembly by the edges to prevent physical abrasion or contamination of the coating, which could reduce its effectiveness in corrosive or high-humidity environments.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52948747780405,"sku":"IS200STCIH4A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200STCIH4A.png?v=1780296076","url":"https:\/\/www.5gplc.com\/products\/ge-is200stcih4a-mark-vie-simplex-contact-input-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}