{"product_id":"ge-is200stcih2a-terminal-board","title":"GE IS200STCIH2A Terminal Board","description":"\u003cp\u003eConfigured for contact input signal acquisition in Mark VI control systems, the \u003cstrong\u003eGeneral Electric IS200STCIH2A\u003c\/strong\u003e (\u003cstrong\u003eIS200STCIH2A\u003c\/strong\u003e Terminal Board) provides direct physical\/electrical execution of high-density signal termination and noise suppression.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STCIH2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Inputs\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003e24, 48, 125 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003ePAIC I\/O Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe IS200STCIH2A facilitates communication between field contacts and the controller through the integrated PAIC I\/O pack. The module utilizes a D-type connector to interface with the I\/O pack, which subsequently manages Ethernet-based data transmission to the host controller. The design incorporates dedicated filtering circuits for each input channel, providing surge protection and high-frequency noise suppression to maintain signal integrity. In a simplex configuration, the board supports variable DC excitation levels, requiring careful monitoring of firmware flash compatibility within the PAIC pack to ensure accurate state transition detection during rapid contact polling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IS200STCIH2A be used in redundant I\/O configurations?\u003c\/p\u003e\n\u003cp\u003eA: No, this terminal board is strictly limited to simplex system architectures. It does not support TMR or redundant I\/O pack pairings.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the onboard noise suppression circuits?\u003c\/p\u003e\n\u003cp\u003eA: The circuits are designed to mitigate surge voltages and high-frequency electrical noise originating from external field wiring, ensuring that the contact input state is correctly interpreted by the PAIC I\/O pack.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The board is suitable for either DIN-rail or flat-panel installation. Ensure the mounting surface is conductive or provided with a dedicated ground strap to maintain chassis potential.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Termination:\u003c\/strong\u003e Terminate field contact wiring directly to the board terminals. Observe proper polarity for the external 24, 48, or 125 V dc excitation sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Pack Seating:\u003c\/strong\u003e Carefully align the PAIC I\/O pack with the board-mounted D-type connector. Apply even pressure to ensure a secure friction fit; improper seating can result in intermittent communication loss over the Ethernet link.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e To maintain the efficacy of the noise suppression features, ensure that all input cables are properly shielded and that shields are terminated to the designated ground lugs on the terminal board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Post-installation, perform a loop check by manually toggling field contacts to verify state changes are accurately reported in the control system HMI.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52988708520245,"sku":"IS200STCIH2A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200STCIH2A.png?v=1781161166","url":"https:\/\/www.5gplc.com\/products\/ge-is200stcih2a-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}