{"product_id":"ge-is200srtdh2acb-rtd-input-terminal-board","title":"GE IS200SRTDH2ACB RTD Input Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200SRTDH2ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200SRTDH2ACB\u003c\/strong\u003e RTD Input Terminal Board, operates as a dedicated hardware component for temperature sensor signal acquisition and conditioning within Mark VIe control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200SRTDH2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.7 cm x 14.8 cm x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial rated range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD Input Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003ePrinted circuit board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IS200SRTDH2ACB module manages backplane bus communication velocity by facilitating the conversion of resistance temperature detector (RTD) analog inputs into digital signals for processing by the I\/O pack. The board maintains deterministic signal integrity, ensuring that temperature data remains synchronized with the controller's scan cycle. Firmware flash compatibility is governed by the associated I\/O pack, which monitors the terminal board's status and ensures the validity of sensor readings. I\/O density scaling is supported through standard terminal block arrangements, providing a localized interface for multiple RTD channels while isolating sensitive signal paths from high-power electromagnetic interference within the control cabinet.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200SRTDH2ACB board hot-swappable during system operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Replacement requires the associated I\/O pack to be de-energized to prevent current spikes or potential damage to the RTD input circuitry during the removal or installation process.\u003c\/p\u003e\n\u003cp\u003eQ: How is signal shielding handled on the IS200SRTDH2ACB?\u003c\/p\u003e\n\u003cp\u003eA: The board provides dedicated terminals for sensor shield termination. Shields must be connected to the cabinet ground bus at the terminal board to minimize noise pickup and maintain measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the board in a clean, dry location within the control cabinet. Ensure the mounting surfaces are free of debris to prevent mechanical stress on the printed circuit board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate RTD leads to the terminal blocks according to the system wiring diagram. Ensure that 3-wire RTD configurations are correctly mapped to provide lead-resistance compensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the board chassis to the cabinet ground using the designated earthing points. Verify that the shield termination strip has a low-impedance path to the system ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Verify that ambient temperatures remain within specified industrial operating limits. Prevent exposure to condensation or corrosive environments that could degrade signal terminal contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Prior to system integration, use a calibrated resistor simulator to verify the input channel accuracy for each RTD point, confirming that the digital value reported by the controller matches the input resistance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52938358030645,"sku":"IS200SRTDH2ACB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200SRTDH2ACB.png?v=1780048793","url":"https:\/\/www.5gplc.com\/products\/ge-is200srtdh2acb-rtd-input-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}