{"product_id":"ge-is200jpdmg1acc-power-distribution-card","title":"GE IS200JPDMG1ACC Power Distribution Card","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200JPDMG1ACC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200JPDMG1\u003c\/strong\u003e Power Distribution Card, operates as a dedicated hardware component for localized power distribution and individual circuit protection to I\/O packs within GE Mark VIe Control Systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200JPDMG1ACC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VIe DIN-Rail PCB Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Power Distribution \/ Circuit Protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Power Input\u003c\/td\u003e\n\u003ctd\u003e125 VDC Nominal Battery Source or Converted 120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaisy-Chain Port Type\u003c\/td\u003e\n\u003ctd\u003eJ1 and J1X Daisy-Chain Bus Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Certification\u003c\/td\u003e\n\u003ctd\u003eClass 1 Division 2 \/ ATEX Zone 2 Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Components\u003c\/td\u003e\n\u003ctd\u003e24 Varistors and 24 Two-Position Plugs (3 Rows of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IS200JPDMG1ACC card routes conditioned DC power directly to individual rack-mounted I\/O packs, isolating transient overvoltage spikes through 24 onboard metal oxide varistors. By offloading power management and short-circuit protection execution from the central controller racks, the board stabilizes local DC supply voltages and prevents power-fault propagation that could disrupt backplane bus communication velocity across the Mark VIe control architecture. The passive distribution topology operates independently of digital logic, ensuring continuous firmware flash compatibility across all Mark VIe control system software updates and module replacements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the current limitations when daisy-chaining multiple IS200JPDMG1ACC boards via J1 and J1X connectors?\u003c\/p\u003e\n\u003cp\u003eA: The total current draw of all daisy-chained boards must not exceed the maximum current rating of the primary J1 input plug on the first JPDH board in the chain.\u003c\/p\u003e\n\u003cp\u003eQ: How are individual I\/O pack power lines protected against electrical faults on the IS200JPDMG1ACC?\u003c\/p\u003e\n\u003cp\u003eA: The board incorporates 24 onboard varistors alongside 24 two-position plug terminals, arranged in three rows of eight, to provide discrete overvoltage protection and localized branch fusing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect the main 125 VDC battery power feed or AC conversion source before touching input power connections.\u003c\/li\u003e\n\u003cli\u003eVerify Class 1 Division 2 or ATEX Zone 2 hazardous location compliance before opening protective enclosures in classified areas.\u003c\/li\u003e\n\u003cli\u003eSecure the IS200JPDMG1ACC card onto the enclosure mounting base using proper grounding hardware to ensure varistor surge suppression pathways to earth ground.\u003c\/li\u003e\n\u003cli\u003eWire input power leads to the main J1 terminal, verifying that downstream daisy-chained connections via J1X remain within total input plug current limits.\u003c\/li\u003e\n\u003cli\u003eConnect output power leads to the two-position plugs, ensuring shield lines are grounded at the system common point.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53272341152053,"sku":"IS200JPDMG1ACC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200JPDMG1A_18582ee5-2450-48d0-8a8c-26b80ce87865.png?v=1786513550","url":"https:\/\/www.5gplc.com\/products\/ge-is200jpdmg1acc-power-distribution-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}