{"product_id":"ge-is200epsmg2a-exciter-power-supply-module","title":"GE IS200EPSMG2A Exciter Power Supply Module","description":"\u003cp\u003eConfigured for power conversion in EX2100 excitation control systems, the \u003cstrong\u003eGE IS200EPSMG2A\u003c\/strong\u003e (\u003cstrong\u003eIS200EPSMG2A\u003c\/strong\u003e Exciter Power Supply Module) provides direct physical and electrical execution of DC voltage regulation for internal system components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EPSMG2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.9 cm x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-bus dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eThe IS200EPSMG2A module functions as a primary power distribution node within the EX2100 excitation architecture. The module regulates input supply to provide stable DC outputs to sensitive controller electronics, ensuring that backplane bus communication velocity is maintained during transient load conditions. Firmware flash compatibility is managed through the host excitation controller to ensure that power management parameters remain aligned with system-wide diagnostic reporting. I\/O density scaling is supported through the module's standardized footprint, which facilitates integration into simplex or redundant power architectures, maintaining electrical isolation between the primary power input and the downstream excitation control circuitry.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200EPSMG2A support hot-swapping while the EX2100 system is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Replacement of this power supply module must be performed with the system de-energized and verified to a zero-energy state to prevent damage to the backplane power pins and associated control logic.\u003c\/p\u003e\n\u003cp\u003eQ: How is the module monitored by the EX2100 control system?\u003c\/p\u003e\n\u003cp\u003eA: The module reports status data to the primary processor, allowing for the real-time monitoring of output voltage stability and module internal health diagnostics.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module within the EX2100 cabinet chassis. Ensure that all mating backplane connectors are properly aligned to prevent pin deformation during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Verify that input supply leads are terminated with the correct polarity. Ensure that all power cabling is sized appropriately to minimize voltage drop and heat generation at the terminal connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the module's designated chassis ground point to the cabinet common ground bus to maintain electrical safety and reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain the cabinet ambient temperature between -30 deg C and 65 deg C. Ensure that airflow pathways around the module heat sinks are not obstructed to prevent thermal shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Following installation, use the EX2100 maintenance terminal to confirm that the output voltage rails are within specified operating limits before engaging the excitation system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52938237247797,"sku":"IS200EPSMG2A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IS200EPSMG2A.png?v=1780047216","url":"https:\/\/www.5gplc.com\/products\/ge-is200epsmg2a-exciter-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}