{"product_id":"ge-fanuc-ds200dcfbg1blc-dc-power-supply-feedback-board","title":"GE Fanuc DS200DCFBG1BLC DC Power Supply Feedback Board","description":"\u003cp\u003eConfigured for power conversion and regulation in EX2000, DC2000, and associated drive platforms, the \u003cstrong\u003eGE DS200DCFBG1BLC\u003c\/strong\u003e (\u003cstrong\u003eDS200DCFBG1\u003c\/strong\u003e DC Power Supply Feedback Board) provides direct physical power distribution and control-level voltage regulation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200DCFBG1BLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e38 V AC and 115 V AC (derived from CPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 V DC, +\/- 15 V DC, +\/- 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DS200DCFBG1BLC serves as the primary power management interface for drive control processors, utilizing an integrated regulation circuit to maintain deterministic voltage levels. The board supports I\/O density scaling through its dedicated motor field power circuits and gate pulse generator drivers. Firmware flash compatibility is governed by the drive control board (SDCC\/LDCC), which monitors the \/PSEN signal; this signal triggers a micro-processor reset if the onboard +5 V DC supply deviates from regulation, ensuring system-wide stability during input power fluctuations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the \/PSEN signal interact with the drive controller?\u003c\/p\u003e\n\u003cp\u003eA: The \/PSEN signal on terminal 2PL monitors the +5 V DC regulation state. When the supply is within limits, the signal is at a TTL low state. If the output voltage drops out of regulation, the signal transitions to a high state, initiating a hardware reset on the Drive Control Card.\u003c\/p\u003e\n\u003cp\u003eQ: What is the load capacity for the +\/- 15 V DC outputs?\u003c\/p\u003e\n\u003cp\u003eA: Each +\/- 15 V DC output is rated at 0.8 A. Of this total current capacity, 0.25 A is available for external loading beyond the requirements of the board's internal circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Verification\u003c\/strong\u003e: Before energizing, verify that the Control Power Transformer (CPT) outputs are stable at 38 V AC (+10%). Incorrect input voltage levels will prevent the internal full-wave rectification and filtering circuits from producing the required unregulated +\/- 24 V DC levels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Handling\u003c\/strong\u003e: Ensure all field wiring is disconnected before board removal. When installing, ensure the board is securely fastened to the chassis to maintain the ground reference required for the feedback circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: To maintain signal integrity of the SCR gate pulse generators and feedback loops, ensure that cable shields are properly terminated at the enclosure ground points to prevent electromagnetic interference from affecting the power regulation outputs.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52991689556277,"sku":"DS200DCFBG1BLC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200DCFBG1BLC.png?v=1781247835","url":"https:\/\/www.5gplc.com\/products\/ge-fanuc-ds200dcfbg1blc-dc-power-supply-feedback-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}