{"product_id":"ge-ds200tcqbg1bcb-mark-v-series-rst-extended-analog-i-o-board","title":"GE DS200TCQBG1BCB Mark V Series RST Extended Analog I\/O Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200TCQBG1BCB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRST Extended Analog I\/O Board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the General Electric\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol framework. This specialized module expands the system's interface capabilities by providing 12 dedicated relay channels for complex turbine control logic. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock, ensuring your Speedtronic system maintains factory-spec signal integrity and response times.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCQBG1BCB utilizes high-performance surface mount technology (SMT) to deliver precise I\/O control within a compact footprint:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 V DC @ 6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN-Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSurface Mount (SMT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.9 cm (H) x 17.8 cm (W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Space Utilization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board utilizes high-density surface mount technology and a DIN-rail mounting profile. This allows engineers to install the module in crowded control cabinets where space remains at a premium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module operates reliably in temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-30°C up to +65°C\u003c\/strong\u003e. This wide thermal envelope ensures stable performance in unconditioned turbine enclosures or remote desert environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Logic Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe +5 V DC power requirement at 6 A provides the necessary current overhead to drive multiple high-speed I\/O signals simultaneously without voltage sagging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Switching Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwelve independent relay channels allow the Mark V system to manage diverse auxiliary functions, providing physical isolation between control logic and field-side actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Deployment Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN-Rail Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the DIN-rail remains free of debris and is securely grounded before snapping the DS200TCQBG1BCB into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Sequencing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the 28 V DC supply meets the board's requirements before initializing the +5 V DC logic power. Correct sequencing prevents latch-up conditions during startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain at least 2 cm of clearance around the board to facilitate natural convection, especially when operating near the upper limit of the +65°C temperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this DS200TCQBG1BCB board ready for immediate deployment?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit in stock. It arrives ready for installation without the need for the repairs or cleaning associated with refurbished units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the \"BCB\" suffix indicate a specific version?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"BCB\" suffix represents the functional and artwork revision level. This version includes all cumulative hardware updates intended for the RST Extended Analog I\/O series within the Mark V ecosystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary mounting requirements?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board features a standard DIN-rail mounting clip. This design simplifies the installation process and ensures the board remains vibration-resistant within the turbine control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board handle sub-zero environments?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolutely. The DS200TCQBG1BCB withstands temperatures as low as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-30°C\u003c\/strong\u003e, making it suitable for cold-start turbine operations in northern climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52799901040949,"sku":"DS200TCQBG1BCB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200TCQBG1BCB.png?v=1777428714","url":"https:\/\/www.5gplc.com\/products\/ge-ds200tcqbg1bcb-mark-v-series-rst-extended-analog-i-o-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}