{"product_id":"ge-ds200stbag1acb-mark-v-series-basic-drive-terminal-board","title":"GE DS200STBAG1ACB Mark V Series Basic Drive Terminal Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200STBAG1ACB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBasic Drive Terminal Board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin General Electric’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark V Series\u003c\/strong\u003e. This board functions as the primary interface for I\/O signals, leveraging the legacy of Speedtronic control technology. It facilitates seamless communication between the drive control board and the DC power supply, ensuring precise signal routing for industrial automated systems. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original equipment to guarantee peak performance in mission-critical environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table outlines the core hardware parameters for the DS200STBAG1ACB:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE General Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSTBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Drive Terminal Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNormal Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Connectivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnectors 6PL, 8PL (Control), 4PL (DC Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSerial Port for Diagnostics \u0026amp; Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstruction Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGEI-100177\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Signal Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe STBA board utilizes dedicated 6PL and 8PL connectors to bridge the gap between drive control logic and physical I\/O, eliminating signal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostic Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated serial port allows engineers to execute real-time troubleshooting and configuration directly at the hardware level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Revision Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs the \"ACB\" version, this board incorporates three significant functional and artwork revisions over the original DS200STBAG1 parent board, offering superior circuit stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Mechanical Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe design employs standoff posts and lock washers to isolate the PCB from vibration, protecting sensitive surface-mount components from mechanical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Handling Guidelines\u003c\/h3\u003e\n\u003cp\u003eProfessional installation ensures longevity. Follow these technical protocols:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Migration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must transfer all hardware jumpers from the decommissioned board to the new DS200STBAG1ACB to replicate your specific system configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRibbon Cable Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways grip the connector housing when disconnecting ribbon cables. Never pull on the ribbon cable itself, as this compromises the wire-to-terminal crimp.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a level orientation during installation. Avoid contact with the cabinet frame or adjacent modules to prevent electrostatic discharge (ESD) or physical trace damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNote that connectors CP1PL through CP4PL, CI1PL, CI5PL, CI7PL, and the Y-series interlock\/brake circuits support GE factory-specific testing; do not modify these during standard field installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DS200STBAG1ACB replace older DS200STBAG1 versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This unit includes the A, C, and B revisions, making it a more advanced and stable version of the original STBA parent board while maintaining backward compatibility within the Mark V Series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should I take regarding the lock washers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure you do not drop lock washers into the drive during installation. These metallic components can cause short circuits or physical damage to the lower PCB stacks if not recovered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I unlock the latched cable connectors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSeveral high-security connectors on this board feature manual latches. You must press the latch mechanism to release the lock before pulling the connector to avoid damaging the board-side headers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52799862309173,"sku":"DS200STBAG1ACB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200STBAG1ACB.png?v=1777427455","url":"https:\/\/www.5gplc.com\/products\/ge-ds200stbag1acb-mark-v-series-basic-drive-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}