{"product_id":"ge-ds200rtbag2aeb-relay-terminal-board","title":"GE DS200RTBAG2AEB Relay Terminal Board","description":"\u003cp\u003eConfigured for input and output signal interfacing in Mark V and EX2000 excitation control architectures, the \u003cstrong\u003eGE DS200RTBAG2AEB\u003c\/strong\u003e (\u003cstrong\u003eDS200RTBAG2AEB\u003c\/strong\u003e Relay Terminal Board) provides direct physical\/electrical execution. It handles field wire terminations, relay signal routing, and status feedback monitoring across dedicated control backplane interfaces without adding latency to the main processor frame.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200RTBAG2AEB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V System Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Bus Draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003eMultiple I\/O Relay Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eIntegrated Real-Time Diagnostic Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark V and EX2000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200RTBAG2AEB\u003c\/strong\u003e operates directly on internal bus architectures, leveraging backplane bus communication velocity protocols to ensure real-time relay state execution and feedback signal digitization. Built-in onboard hardware diagnostics scan channel continuity, maintaining strict firmware flash compatibility across systemic controller hardware updates and facilitating high I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are diagnostic signals processed on the DS200RTBAG2AEB board?\u003c\/p\u003e\n\u003cp\u003eA: Onboard monitoring circuitry tracks relay contact states and coil continuity, transmitting real-time fault indicators directly to the primary Mark V core processor via backplane communications.\u003c\/p\u003e\n\u003cp\u003eQ: Can the board be installed while the control rack is fully energized?\u003c\/p\u003e\n\u003cp\u003eA: No, control power and high-voltage field wiring connected to relay contacts must be completely isolated before inserting or removing terminal board wiring connectors.\u003c\/p\u003e\n\u003cp\u003eQ: Is the DS200RTBAG2AEB backwards compatible with EX2000 system racks?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the board is engineered with standard physical mounting layouts and connector pinouts compatible with both GE Mark V and EX2000 excitation system cabinets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all incoming power sources and verify zero voltage across relay field contacts before commencing installation.\u003c\/li\u003e\n\u003cli\u003eAlign the board with the designated mounting standoffs inside the Mark V or EX2000 enclosure frame.\u003c\/li\u003e\n\u003cli\u003eFasten all retaining hardware to establish structural stability and ensure a solid chassis ground connection.\u003c\/li\u003e\n\u003cli\u003eRoute field control wiring away from high-voltage AC cables, terminating conductors securely into the labeled terminal strip screws.\u003c\/li\u003e\n\u003cli\u003eInspect ribbon cable connections to main processor boards to verify correct pin alignment before re-energizing the rack assembly.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53438881038645,"sku":"DS200RTBAG2AEB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200RTBAG2AEB.png?v=1788244843","url":"https:\/\/www.5gplc.com\/products\/ge-ds200rtbag2aeb-relay-terminal-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}