{"product_id":"ge-ds200ldcch1aka-mark-v-speedtronic-drive-control-and-lan-communications-board","title":"GE DS200LDCCH1AKA Mark V Speedtronic Drive Control and LAN Communications Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200LDCCH1AKA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDrive Control and LAN Communications Board (LDCC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Mark V Speedtronic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. This high-performance module executes core control algorithms and manages high-speed data exchange between the turbine control core and peripheral I\/O boards. By utilizing the Intel 80196 microcontroller, this board synchronizes complex drive operations with nanosecond precision. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring your system operates with peak original manufacturer performance and factory-certified stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200LDCCH1AKA integrates a robust electrical architecture to handle mission-critical industrial automation tasks:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic DS200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntel 80196 Microcontroller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOnboard Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated EPROM + RAM (Firmware \u0026amp; Data)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLAN Interface + Dedicated Serial Diagnostic Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePCB Coating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coating (Moisture\/Dust Resistance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Revisions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision A (1st), Revision K (2nd)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArtwork Revision\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Onboard Fuses \u0026amp; LED Fault Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Computational Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Intel 80196 microcontroller processes real-time data from turbine sensors and executes drive regulation commands without perceptible latency, maintaining tight control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsolidated Communication Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board integrates drive control and LAN communications into a single PCB. This consolidated design reduces the physical footprint in the control cabinet and simplifies the communication bus between the controller and I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Conformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specialized conformal coating protects delicate surface-mount components from humidity, salt air, and airborne contaminants typical of power generation environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Diagnostic Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnboard serial ports allow engineers to connect a laptop directly to the LDCC board for real-time monitoring. The LED fault indicators provide immediate visual feedback, accelerating the troubleshooting process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated EPROM chips store critical system firmware securely, preventing data corruption during power cycles or emergency shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; System Protocol\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrostatic Discharge (ESD) Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways wear a grounded wrist strap when handling the DS200LDCCH1AKA. The high-density Intel microcontroller remains highly sensitive to static discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the EPROM chips on the new board match your specific turbine requirements. You may need to transfer existing chips if your system utilizes site-specific custom control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExercise extreme caution when mating the board with the turbine backplane. The high-density pin connectors require precise alignment to prevent bent pins and intermittent communication failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuse Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that all onboard fuses remain intact before powering up the drive to prevent initialization errors during the \"Power-On Self-Test\" (POST).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the Intel 80196 processor on this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Intel 80196 acts as the central logic processor. It interprets signals from turbine sensors, manages the LAN communication traffic, and executes the control loops necessary to regulate turbine speed and torque.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the DS200LDCCH1AKA replace an older LDCC board with different revision levels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. This \"AKA\" revision typically maintains backward compatibility within the Mark V series. However, you must verify your drive's firmware version via the serial port to ensure the software supports the specific hardware features included in Revision K.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the conformal coating improve board longevity?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe conformal coating provides a non-conductive protective layer that insulates the circuitry from environmental stressors like dust, moisture, and chemical vapors, effectively preventing corrosion and electrical shorts in turbine control cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the board arrive with pre-installed RAM and EPROM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit includes factory-standard RAM and EPROM chips. For specialized turbine applications, engineers often swap the EPROM chips to match the unique control parameters and custom logic of the specific installation site.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52800147718453,"sku":"DS200LDCCH1AKA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200LDCCH1AGA_5b67bfe8-bf6a-4aa9-95b3-155f3f98ce30.jpg?v=1777432740","url":"https:\/\/www.5gplc.com\/products\/ge-ds200ldcch1aka-mark-v-speedtronic-drive-control-and-lan-communications-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}