{"product_id":"ge-8811-io-dc-safetynet-discrete-i-o-module","title":"GE 8811-IO-DC SafetyNet Discrete I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE 8811-IO-DC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8811-IO-DC\u003c\/strong\u003e SafetyNet Discrete Input\/Output Module, operates as a dedicated hardware component for safe field signal acquisition and discrete output switching within PAC8000 SafetyNet systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8811-IO-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 mA System Power, 50 mA Field Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eConfigurable Safety Discrete I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan\/Response Speed\u003c\/td\u003e\n\u003ctd\u003e1-8 ms Configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ratings\u003c\/td\u003e\n\u003ctd\u003eInput On-Off: 0.9 mA; Output: 2 A DC per Point (6 A DC Max per Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003eDiscrete or Pulsed Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003ePAC8000 Railbus Interface via Carrier Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 8811-IO-DC module routes discrete channel states and diagnostic flags directly across the high-speed PAC8000 Railbus backplane. Interfacing through the Bus Interface Module (BIM) or Safety Controller, the card maintains deterministic signal scan times configurable between 1 ms and 8 ms. This architecture preserves backplane bus communication velocity across expanded carriers while enforcing strict firmware flash compatibility between safety I\/O nodes and system controllers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing an 8811-IO-DC module require disconnecting the field wiring terminations?\u003c\/p\u003e\n\u003cp\u003eA: No. Field wiring terminates directly onto a separate field terminal block that snaps onto the carrier assembly, allowing module hot-swapping without disturbing field lines.\u003c\/p\u003e\n\u003cp\u003eQ: How is mechanical keying implemented on the 8811-IO-DC module?\u003c\/p\u003e\n\u003cp\u003eA: The PAC8000 carrier and field terminal system utilize a mechanical keying arrangement that prevents inserting an incorrect module type into a keyed slot.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the carrier base onto a standard DIN rail or mount directly to a flat panel frame.\u003c\/li\u003e\n\u003cli\u003eAlign the 8811-IO-DC module connectors with the carrier slot position and press firmly until the locking mechanism engages.\u003c\/li\u003e\n\u003cli\u003eAttach the field terminal block to the carrier adjacent to the module slot until it snaps into place.\u003c\/li\u003e\n\u003cli\u003eRoute discrete field inputs and load circuits to the terminal block, maintaining proper polarity for 24 VDC field power supplies.\u003c\/li\u003e\n\u003cli\u003eVerify that field output load currents do not exceed 2 A DC per channel or 6 A DC total per module to protect internal switching paths.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53271540957493,"sku":"8811-IO-DC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/8811-IO-DC.png?v=1786502983","url":"https:\/\/www.5gplc.com\/products\/ge-8811-io-dc-safetynet-discrete-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}