{"product_id":"ge-369-hi-0-0-0-0-0-e-motor-protection-relay","title":"GE 369-HI-0-0-0-0-0-E Motor Protection Relay","description":"\u003cp\u003eThe \u003cstrong\u003eGE 369-HI-0-0-0-0-0-E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e369\u003c\/strong\u003e Motor Protection Relay, operates as a dedicated hardware component for motor monitoring, fault detection, and thermal overload protection within GE Multilin 369 Motor Management System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-0-0-0-0-0-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE \/ GE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eControl Power: 50-300 VDC \/ 60-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Interface\u003c\/td\u003e\n\u003ctd\u003eEnhanced LED-Backlit Display Window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003e12 Front-Panel Labeled Push Buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Status\u003c\/td\u003e\n\u003ctd\u003e10 Labeled Front-Panel LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eNon-Harsh Environment (Standard Conformal\/Enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 369-HI-0-0-0-0-0-E utilizes an internal micro-controller architecture to process phase currents, ground faults, and thermal models in real time. Backplane bus communication velocity is maintained across high-speed serial links, ensuring rapid trip signal output execution during overcurrent or phase imbalance conditions. The internal memory supports firm, verified firmware flash compatibility to allow seamless integration into automated power management networks without risking configuration drift or protocol mismatch.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 369-HI-0-0-0-0-0-E support direct connection of RTD temperature sensors?\u003c\/p\u003e\n\u003cp\u003eA: No. The second \"0\" in the model matrix indicates that the 12 built-in RTD inputs are absent on this hardware option. External RTD module expansion is required if direct temperature sensing is needed.\u003c\/p\u003e\n\u003cp\u003eQ: What control power voltage ranges are supported by the \"HI\" power supply option?\u003c\/p\u003e\n\u003cp\u003eA: The \"HI\" power supply option accepts either 50-300 VDC or 60-265 VAC at 50\/60 Hz control power sources.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all high-voltage feeder circuits and control power sources before installing or servicing the relay.\u003c\/li\u003e\n\u003cli\u003eMount the 369-HI-0-0-0-0-0-E securely in the switchgear panel cutout using the four backplane mounting screws.\u003c\/li\u003e\n\u003cli\u003eConnect dedicated Earth ground to the rear panel ground terminal using minimum 12 AWG copper wire to ensure EMI shielding and electrical safety.\u003c\/li\u003e\n\u003cli\u003eWire the 50-300 VDC \/ 60-265 VAC control power lines to the designated power terminals using shielded wire runs.\u003c\/li\u003e\n\u003cli\u003eTerminate current transformer (CT) secondary leads securely, ensuring proper shorting blocks are utilized prior to disconnecting any secondary loop.\u003c\/li\u003e\n\u003cli\u003eVerify all terminal connection torques and ensure front-panel LED diagnostics illuminate correctly during power-on initialization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53271463362869,"sku":"369-HI-0-0-0-0-0-E","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/369-HI-0-0-0-0_c5f90f9d-4fd4-4e57-b132-eb8497fbd5b2.jpg?v=1786500734","url":"https:\/\/www.5gplc.com\/products\/ge-369-hi-0-0-0-0-0-e-motor-protection-relay","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}