{"product_id":"fta-t-14-honeywell-analog-input-fta-module","title":"FTA-T-14 | Honeywell | Analog Input FTA Module","description":"\u003cp\u003eConfigured for high-density signal acquisition in Honeywell control platforms, the \u003cstrong\u003eHoneywell FTA-T-14\u003c\/strong\u003e (\u003cstrong\u003eFTA-T-14\u003c\/strong\u003e Analog Input Module) provides direct physical and electrical execution of analog and digital field signal termination. The assembly manages 14 discrete channels, facilitating the transmission of temperature, pressure, and current-based process data to the primary control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-T-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e114 x 99 x 72 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog (Temp, Pressure, Current), Digital (Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 V to +10 V or 0 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe FTA-T-14 module incorporates channel-to-channel isolation to prevent ground potential variations from impacting signal integrity. This design ensures that each of the 14 inputs remains electrically distinct, minimizing common-mode noise propagation between disparate process loops. The architecture is compatible with 4-20 mA HART loop protocol standards, allowing for the direct integration of intelligent field transmitters without the need for additional signal conversion. Cold junction compensation (CJC) is managed via integrated circuitry to maintain measurement accuracy for thermocouples within the specified input ranges.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping while the system backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: The FTA-T-14 is intended for permanent installation on DIN rail systems. Hot-swapping is not supported; module removal or insertion under power risks inducing transient surges that may interfere with the 1000 Hz sampling synchronization and potential damage to the input buffers.\u003c\/p\u003e\n\u003cp\u003eQ: How should the module be configured for digital switch status inputs?\u003c\/p\u003e\n\u003cp\u003eA: Digital inputs must be wired to the module terminals according to the specific voltage threshold requirements of the controller. Ensure that the input signal impedance and voltage levels do not exceed the module's rated -10 V to +10 V operating range to prevent damage to the interface circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSecure the FTA-T-14 onto the DIN rail; ensure the housing is firmly locked to prevent vibration-induced movement.\u003c\/li\u003e\n\u003cli\u003eRoute field signal wiring through separate cable trays from high-voltage power lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate all shielded cables to the cabinet's master ground busbar to maintain proper shielding potential and reduce noise.\u003c\/li\u003e\n\u003cli\u003eVerify input signal polarity for all 14 channels before initiating system power-up.\u003c\/li\u003e\n\u003cli\u003ePerform a loop check by applying a calibrated signal (4 mA and 20 mA or known voltage) at the field terminal and verifying the corresponding digital value within the controller software.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52975892431157,"sku":"FTA-T-14","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FTA-T-141.png?v=1780987817","url":"https:\/\/www.5gplc.com\/products\/fta-t-14-honeywell-analog-input-fta-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}