{"product_id":"fs-sicc-0001-l7-honeywell-system-interconnection-cable","title":"FS-SICC-0001\/L7 Honeywell System Interconnection Cable","description":"\u003cp\u003eConfigured for high-integrity inter-rack signal routing in FSC and Experion systems, the \u003cstrong\u003eHoneywell FS-SICC-0001\/L7\u003c\/strong\u003e (\u003cstrong\u003eFS-SICC-0001\u003c\/strong\u003e System Interconnection Cable) provides direct physical\/electrical execution. It links chassis modules using a factory-terminated 20-core conductor path across a 7 m length.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SICC-0001\/L7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eOuter Diameter Approx 9.93 mm x 7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive interconnect assembly (Zero internal power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e20-core, AWG 22 (approx 0.34 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eDouble-shielded for EMI\/RFI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eFactory-terminated for Honeywell chassis modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell FSC and Experion systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Signal Interconnection Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FS-SICC-0001\/L7 cable assembly features channel-to-channel isolation principles to suppress electromagnetic interference and radio frequency noise across industrial control environments. Utilizing double-shielded AWG 22 conductors, the physical cable layer limits signal attenuation and cross-talk during parallel routing. The assembly transports discrete safety telemetry and 4-20 mA HART loop protocol field signals between central processing racks and remote termination sub-assemblies without line distortion over the 7 m span.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FS-SICC-0001\/L7 cable be disconnected while the host system remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Disconnection during active operation is permissible only within parallel redundant communication configurations; removing a single-channel cable severs active I\/O communication to the central controller.\u003c\/p\u003e\n\u003cp\u003eQ: How does double-shielding impact signal integrity in high-EMI noise environments?\u003c\/p\u003e\n\u003cp\u003eA: The outer foil and braided shield layers isolate internal AWG 22 conductors from external high-frequency electrical fields, preventing induced voltages from corrupting low-level analog loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting and Bending Limits\u003c\/strong\u003e: Route the cable assembly through dedicated wire trays or conduit. Maintain a minimum static bending radius of 60 mm to avoid damaging the outer jacket or internal foil shield.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Engagement\u003c\/strong\u003e: Align factory-terminated pin headers precisely with chassis module connectors before applying seating force. Secure mechanical retention screws to maintain a vibration-proof electrical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Ensure shield drain terminations bond to the cabinet main earth bar at a single grounding point to eliminate ground potential loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Line Segregation\u003c\/strong\u003e: Maintain a minimum 30 cm separation distance between the interconnection cable and high-voltage AC power wiring within cabinet raceways.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53497434603829,"sku":"FS-SICC-0001\/L7","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FC-SICC-0001L10_Cocoai_f7298d17-ff76-4776-8d4f-237ab0d10b97.png?v=1788846510","url":"https:\/\/www.5gplc.com\/products\/fs-sicc-0001-l7-honeywell-system-interconnection-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}