{"product_id":"fs-sicc-0001-l24-honeywell-system-interconnection-cable","title":"FS-SICC-0001\/L24 Honeywell System Interconnection Cable","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-SICC-0001\/L24\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFS-SICC-0001\/L24\u003c\/strong\u003e System Interconnection Cable, operates as a dedicated hardware component for high-integrity signal routing between I\/O modules and Field Termination Assemblies (FTAs) within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SICC-0001\/L24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNetherlands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e24 m length, 9.93 mm outer diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive interconnect assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e20 x AWG 22 (0.34 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e120 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eDouble shielded for EMI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003ePre-terminated Honeywell-compatible connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant, UL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe FS-SICC-0001\/L24 interconnect cable maintains physical and electrical signal segregation across its 20 AWG 22 copper conductors when bridging Safety Manager subracks to termination units. Integrated double shielding limits electromagnetic interference (EMI) and prevents capacitive cross-talk from degrading sensitive 4-20 mA HART loop protocol signals. Combined with a 120 Ohm characteristic impedance match, the assembly preserves channel-to-channel isolation parameters and minimizes attenuation across long cabinet-to-cabinet routing runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What does the \"L24\" suffix represent in the module part number?\u003c\/p\u003e\n\u003cp\u003eA: The \"L24\" suffix designates the factory-precut and pre-terminated overall cable length of 24 meters, optimized for fixed interconnect distances between control racks and field termination panels.\u003c\/p\u003e\n\u003cp\u003eQ: How does the double shielding construction protect analog signal transmission?\u003c\/p\u003e\n\u003cp\u003eA: The double shield layer provides continuous 360-degree EMI attenuation, shielding low-voltage loop signals against high-frequency industrial noise and cross-talk from adjacent wiring channels.\u003c\/p\u003e\n\u003cp\u003eQ: Can the cable connectors be re-terminated in the field if cut to a shorter length?\u003c\/p\u003e\n\u003cp\u003eA: Field cutting is not recommended as the cable is factory-assembled with molded, pre-tested Honeywell-compatible connectors designed to maintain grounding continuity and strain relief.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect pre-terminated connector housings and pin contacts for contamination or mechanical distortion prior to engagement.\u003c\/li\u003e\n\u003cli\u003eMaintain the minimum dynamic bend radius during installation to prevent deformation of the outer thermoplastic jacket and shield layers.\u003c\/li\u003e\n\u003cli\u003eAlign keyed connector housings with the target I\/O module and FTA header sockets, pushing straight until the retaining latches click into place.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through dedicated low-voltage instrument ducts, maintaining isolation from high-voltage AC power lines and inverter cabling.\u003c\/li\u003e\n\u003cli\u003eVerify shield ground grounding continuity at the panel earth bus bar according to system grounding specifications.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53515573559605,"sku":"FS-SICC-0001\/L24","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FS-SICC-001L8-IN_8faf1e0e-4b88-40a3-8336-2a7241b2e324.jpg?v=1788920520","url":"https:\/\/www.5gplc.com\/products\/fs-sicc-0001-l24-honeywell-system-interconnection-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}