{"product_id":"foxboro-p0915pg-analog-input-module","title":"Foxboro P0915PG Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eFoxboro P0915PG\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0915PG\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for analog-to-digital signal conversion within Foxboro I\/A Series DCS networks. It converts isolated incoming analog current loop signals from process transmitters into digitized variables for system control execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0915PG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6 x 3 x 1 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e-40 mA to +120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocol Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe Foxboro P0915PG provides galvanically isolated input channels designed to maintain signal integrity and eliminate ground loop interference across extended process loops. This channel-to-channel isolation architecture stabilizes signal acquisition across -40 mA to +120 mA ranges and supports integration with field devices operating on 4-20 mA HART loop protocol communications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the P0915PG prevent common-mode noise propagation to the backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: Galvanic channel-to-channel isolation breaks electrical earth loops between field wiring terminations and logic circuits, isolating high-voltage transients and common-mode noise.\u003c\/p\u003e\n\u003cp\u003eQ: What is the power consumption requirement for a single P0915PG module?\u003c\/p\u003e\n\u003cp\u003eA: The P0915PG operates with a maximum power draw of 2.5 W from the baseplate bus rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the P0915PG module into its designated baseplate slot, ensuring top and bottom retaining clips seat securely into the assembly rails before restoring power.\u003c\/p\u003e\n\u003cp\u003eRoute all analog field input wiring through separate low-voltage wireways, keeping signal lines isolated from high-voltage AC lines. Ground cable drain shields at a single point on the cabinet earthing bar. Where conduit penetrations enter the cabinet, ensure NPT fittings achieve a minimum of 5 full threads of engagement to maintain physical strain relief and enclosure integrity.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53394596987189,"sku":"P0915PG","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM222P0926TL2_71efce20-04a7-49f2-b195-c0641897669e.png?v=1787562845","url":"https:\/\/www.5gplc.com\/products\/foxboro-p0915pg-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}